Продукція > CHAUVIN ARNOUX > Всі товари виробника CHAUVIN ARNOUX (698) > Сторінка 2 з 12

Обрати Сторінку:    << Попередня Сторінка ]  1 2 3 4 5 6 7 8 9 10 11 12  Наступна Сторінка >> ]
Фото Назва Виробник Інформація Доступність
Ціна
без ПДВ
C.A 6424 C.A 6424 CHAUVIN ARNOUX ca-6422-24-EN.pdf ca-6422-24-DE.pdf NF_CA6422_24_GB.pdf NF_CA6422_24_DE.pdf Category: Earth Resistance Meter
Description: Meter: grounding resistance; LCD; 0.05÷50kΩ; IP65; Illumin: yes
Body dimensions: 223x126x70mm
Conform to the norm: CAT IV 600V; EN 61010; EN 61557
Illumination: yes
Standard equipment: carrying case; mains cable; power supply; user's manual
Type of meter: grounding resistance
Weight with battery: 1kg
Earthing resistance measuring accuracy: ±(2% + 1 digits)
Alias: P01127014
Earthing resistance measuring range: 0.05...50kΩ
Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6
Kind of display used: LCD
Power supply: rechargeable battery Ni-MH AA x6
IP rating: IP65
товар відсутній
C.A 6462
+1
C.A 6462 CHAUVIN ARNOUX Category: Earth Resistance Meter
Description: Meter: grounding resistance; LCD; (2000); 10mΩ÷20Ω,200Ω,2kΩ; IP53
IP rating: IP53
Body dimensions: 273x247x127mm
Conform to the norm: EN 61010-2-032; EN 61557
Illumination: yes
Standard equipment: user's manual
Type of meter: grounding resistance
Weight with battery: 3.35kg
Earthing resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ
Battery/ rechargeable battery: rechargeable battery Ni-MH x1
Display parameters: (2000)
Earthing resistance measuring accuracy: ±(2% + 1 digit)
Kind of display used: LCD
Power supply: rechargeable battery Ni-MH x1
товар відсутній
C.A 6503 C.A 6503 CHAUVIN ARNOUX CA-6503_M.PDF Category: Insulation Resistance Meters
Description: Meter: insulation resistance; analogue; 250V,500V,1kV; IP54
Type of meter: insulation resistance
Kind of display used: analogue
Insulation resistance measuring accuracy: ±2.5%
Test voltage: 250V; 500V; 1kV
Conform to the norm: CAT II 600V; CAT III 300V; EN 61010
Standard equipment: 3 crocodile clips; carrying case; test leads ( 3pcs.); test probe x1
Power supply: built-in magneto
IP rating: IP54
Weight without batteries: 1.06kg
Body dimensions: 120x120x130mm
Insulation resistance measuring ranges: 1...5000MΩ
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
1+53227.53 грн
C.A 6524 C.A 6524 CHAUVIN ARNOUX CA-6524_DS.PDF CA-6524_M.PDF Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; (4000); VAC: 300mV÷400V,700V
Type of meter: insulation resistance
Kind of display used: LCD
Display parameters: (4000)
AC voltage measuring range: 300mV...400V; 700V
DC voltage measuring range: 300mV...400V; 700V
DC voltage measuring accuracy: ±(3% + 2 digit)
IP rating: IP54
Body dimensions: 211x108x60mm
Weight without batteries: 850g
Power supply: battery LR6 AA 1,5V x6
Conform to the norm: CAT IV 600V; EN 61243-3:2010; IEC 61010-1; IEC 61010-2-030; IEC 61326-1
Continuity test: <10Ω; <100Ω
Standard equipment: carrying case; crocodile clip; test leads; test probe x1
Test voltage: 50V; 100V; 250V; 500V; 1kV
Resistance measuring range: 4kΩ; 40kΩ; 400kΩ; 1MΩ
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Measurement memory: 300
Resistance measuring accuracy: ±(3%+2 digit)
Bargraph: yes
Insulation resistance measuring ranges: 10...999kΩ; 4MΩ; 40MΩ; 400MΩ; 4GΩ; 40GΩ; 200GΩ
Insulation resistance measuring accuracy: ±(3% + 2digit)
товар відсутній
C.A 6526
+7
C.A 6526 CHAUVIN ARNOUX CA-6524_DS.PDF CA-6524_M.PDF Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; (4000); VAC: 300mV÷400V,700V
Body dimensions: 211x108x60mm
Conform to the norm: CAT IV 600V; EN 61243-3:2010; IEC 61010-1; IEC 61010-2-030; IEC 61326-1
IP rating: IP54
Bargraph: yes
Test voltage: 50V; 100V; 250V; 500V; 1kV
Resistance measuring range: 4kΩ; 40kΩ; 400kΩ; 1MΩ
DC voltage measuring range: 300mV...400V; 700V
AC voltage measuring range: 300mV...400V; 700V
Capacitance measuring range: 0.1...400nF; 4µF; 10µF
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: included
Insulation resistance measuring ranges: 10...999kΩ; 4MΩ; 40MΩ; 400MΩ; 4GΩ; 40GΩ; 200GΩ
Display parameters: (4000)
DC voltage measuring accuracy: ±(3% + 2 digit)
Resistance measuring accuracy: ±(3%+2 digit)
Insulation resistance measuring accuracy: ±(3% + 2digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x6
Interface: Bluetooth
Measurement memory: 1300
Standard equipment: carrying case; crocodile clip; test leads; test probe x1
Type of meter: insulation resistance
Weight without batteries: 850g
Continuity test: <10Ω; <100Ω
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+50922.78 грн
C.A 6528 C.A 6528 CHAUVIN ARNOUX CA-6528.pdf Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; (4000); R range: 1÷420kΩ; IP40
Type of meter: insulation resistance
Kind of display used: LCD
Display parameters: (4000)
Resistance measuring range: 1...420kΩ
Insulation resistance measuring accuracy: ±(1.5% + 10digit)
AC voltage measuring range: 0...700V
DC voltage measuring range: 0...700V
Continuity test: <40Ω
Test voltage: 250V; 500V; 1kV
Conform to the norm: IEC 61010-1; IEC 61010-2-030; IEC 61010-2-034; IEC 61326-1
Measuring instrument features: automatic power-off; HOLD function
Standard equipment: carrying case; crocodile clip; test leads; test probe x1
Power supply: battery LR6 AA 1,5V x6
IP rating: IP40
Weight without batteries: 760g
Body dimensions: 218x95x63mm
Insulation resistance measuring ranges: 50kΩ...11GΩ
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: included
Resistance measuring accuracy: ±(1.2%+3 digit)
товар відсутній
C.A 6547 C.A 6547 CHAUVIN ARNOUX CA-6547_DS.PDF CA-6547_M.PDF Category: Insulation Resistance Meters
Description: Meter: megaohm meter; LCD; VAC: 1÷5100V; VDC: 1÷5100V; ±(5%+3digit)
IP rating: IP53
Body dimensions: 270x250x180mm
Interface: RS232
Conform to the norm: CAT III 1000V; EN 61010; IEC 61010-1; IEC 61557
Illumination: yes
Standard equipment: 1 lead with rear connection 0,35m length; carrying case; mains cable; test leads with crocodile clips
Measuring instrument features: settable MIN/MAX alarm thresholds
Type of meter: megaohm meter
Weight without batteries: 4.3kg
Test voltage: 50...5100V
DC voltage measuring range: 1...5100V
AC voltage measuring range: 1...5100V
Insulation resistance measuring ranges: 10kΩ...10TΩ
DC voltage measuring accuracy: ±(5% + 3 digit)
Insulation resistance measuring accuracy: ±(5% + 3digit)
Kind of display used: LCD
Power supply: rechargeable battery Ni-MH 1,2V 3,5Ah x8
Supply voltage: 85...265V AC
товар відсутній
C.A 6608
+4
C.A 6608 CHAUVIN ARNOUX CA-6608-DTE.PDF ca-6608-M.PDF Category: Phase Sequence Indicators
Description: Tester: phase sequence; LCD; Freq: 15÷400Hz; IP40
Type of tester: phase sequence
Kind of display used: LCD
Phase-to-phase voltage range for phase sequence indication: 40...850V AC
Operating frequency: 15...400Hz
IP rating: IP40
Body dimensions: 130x69x32mm
Weight with battery: 130g
Power supply: from tested wiring system
Conform to the norm: CAT III 600V; EN 61010; IEC 61557-7
Measurement: motor's rotation direction; phase sequence
Standard equipment: 3 crocodile clips; case; test leads ( 3pcs.)
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+12651.73 грн
C.A 6609
+6
C.A 6609 CHAUVIN ARNOUX CA-6608-DTE.PDF CA-6609-M.PDF Category: Phase Sequence Indicators
Description: Tester: phase sequence; LED; Freq: 15÷400Hz; IP40
Operating frequency: 15...400Hz
Type of tester: phase sequence
Standard equipment: 3 crocodile clips; case; test leads ( 3pcs.)
Measuring instrument features: non-contact determination of rotation field direction; voltage indicator individual for each phase
Weight with battery: 170g
Phase-to-phase voltage range for phase sequence indication: 40...600V AC
IP rating: IP40
Power supply: battery 9V x1
Measurement: motor's rotation direction; phase sequence
Kind of display used: LED
Body dimensions: 130x69x32mm
Conform to the norm: CAT III 600V; EN 61010; IEC 61557-7
товар відсутній
C.A 6681 C.A 6681 CHAUVIN ARNOUX CA-6681_DS.PDF CA-6681_M.PDF Category: Metals & cables detectors
Description: Wire localizer; LCD; 12÷300VAC,12÷300VDC; Output signal: 125kHz
Kind of display used: LCD
Standard equipment: a bayonet adapter B22; adapter for main socket; a earth spike; a screw adapter E27; case; crocodile clips; receiver; test leads; transmitter
Battery/ rechargeable battery: battery 6LR61 9V x7
Measuring instrument features: detection of a metallic water supply and heating pipe; detection of faults in an in floor heating system; detection of the constricted (plugged) part of nonmetallic pipe; identification of supply circuit on the same floor; identyfication of pairs
Detection: conductors at depth up to 2m (1-pole application); conductors at depth up to 0,5m (2-pole application); localisation of wire breaks; localises discontinuity in live conductors; localizes cable routes in ground; localizes given electric circuit protection; localizes routes of metal pipes for water and central heating systems; locating and tracing lines and outlets
Output signal: 125kHz
Detected voltage range: 12...300V AC; 12...300V DC
Bargraph: yes
Power supply: battery 6LR61 9V x7
Conform to the norm: CAT III 300V; EN 61010
Type of tester: wire localizer
Receiver dimensions: 241.5x78x38.5mm
Transmitter dimensions: 190x89x42.5mm
Additional functions: torch
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
1+30293.85 грн
C.A 702
+2
C.A 702 CHAUVIN ARNOUX CA-703_DS.PDF ca-702-ins.PDF CA-703_M.PDF Category: Portable digital multimeters
Description: Digital multimeter; LCD; (1999); VDC: 200mV,2V,20V,200V,600V
Type of meter: digital multimeter
Measuring instrument features: automatic power-off; autoranging; built-in measuring cables; contactless voltage detector; HOLD function; low battery indicator; pocket size
Kind of display used: LCD
DC voltage measuring range: 200mV; 2V; 20V; 200V; 600V
DC voltage measuring accuracy: ±(0.5% + 3 digit)
AC voltage measuring range: 2V; 20V; 200V; 600V
AC voltage measuring accuracy: ±(1% + 8 digit)
Resistance measuring range: 200Ω; 2kΩ; 20kΩ; 200kΩ; 2MΩ; 20MΩ
Resistance measuring accuracy: ±(0.08%+5 digit)
Diode test: 1mA @1.5V
Continuity test: acoustic indication; <60Ω
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: fixed test leads
Measurement: AC voltage; continuity; DC voltage; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions (W x H x D): 55x104x32.5mm
Additional functions: torch
Display parameters: (1999)
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+3733.12 грн
C.A 7028 CHAUVIN ARNOUX Category: LAN and Telephone Networks Testers
Description: Tester: LAN wiring; LCD; 0÷40°C; 165x90x37mm; Illumin: yes
Type of tester: LAN wiring
Kind of display used: LCD
Detection: discontinuities and short circuits in conductors; place of cable failure; reversed connection; screening continuity; split pairs
Measurement: cable length; continuity
Power supply: battery LR6 AA 1,5V x4
Operating temperature: 0...40°C
Conform to the norm: EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-6; EN 61326-1; IEC 61010-1
Dimensions: 165x90x37mm
Measuring instrument features: automatic power-off; identyfication of pairs; low battery indicator; testing and identifying up to 9 links; voltage presence indicator; wiring schemes: TIA 568A/B, USOC & ISDN
Standard equipment: case; identifier; RJ45 connection cables
Related items: CA-P01101994; CA-P01101995
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Test: cables FTP; cables SSTP; cables STP; cables UTP
Illumination: yes
товар відсутній
C.A 703 C.A 703 CHAUVIN ARNOUX CA-703_DS.PDF CA-703_M.PDF Category: Portable digital multimeters
Description: Digital multimeter; LCD; (1999); VDC: 200mV,2V,20V,200V,600V
Type of meter: digital multimeter
Measuring instrument features: automatic power-off; autoranging; built-in measuring cables; contactless voltage detector; HOLD function; low battery indicator; pocket size
Kind of display used: LCD
DC voltage measuring range: 200mV; 2V; 20V; 200V; 600V
DC voltage measuring accuracy: ±(0.5% + 3 digit)
AC voltage measuring range: 2V; 20V; 200V; 600V
AC voltage measuring accuracy: ±(1% + 8 digit)
AC current measuring range: 0.2mA; 2mA; 20mA; 200mA
DC current measuring range: 0.2mA; 2mA; 20mA; 200mA
DC current measuring accuracy: ±(2% + 8 digit)
AC current measuring accuracy: ±(2.5% + 10 digit)
Resistance measuring range: 200Ω; 2kΩ; 20kΩ; 200kΩ; 2MΩ; 20MΩ
Resistance measuring accuracy: ±(0.08%+5 digit)
Diode test: 1mA @1.5V
Continuity test: acoustic indication; <60Ω
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: fixed test leads
Measurement: AC current; AC voltage; continuity; DC current; DC voltage; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions (W x H x D): 55x104x32.5mm
Additional functions: torch
Display parameters: (1999)
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
1+4736.46 грн
C.A 732 C.A 732 CHAUVIN ARNOUX CA-703_DS.PDF ca-732-ins.PDF Category: Indicators, Voltage & Continuity Testers
Description: Tester: non-contact voltage detector; 195÷265VAC; IP40
Power supply: battery LR03 AAA 1,5V x2
Additional functions: torch
IP rating: IP40
Conform to the norm: CAT III 1000V; EN 61010
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Detected voltage range: 195...265V AC
Type of tester: non-contact voltage detector
Measuring instrument features: contactless voltage detector; ergonomic case ensuring comfortable and precise operation
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
1+2328.75 грн
2+ 2044.51 грн
C.A 742
+4
C.A 742 CHAUVIN ARNOUX CA-762_DS.PDF CA-742_M.PDF Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; VAC: 12V,24V,50V,127V,230V,400V,690V
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: carrying strap; test lead; test probe x1
Body dimensions: 163x64x40mm
IP rating: IP65
Kind of display used: LEDs
Weight with battery: 210g
Conform to the norm: CAT IV 600V; EN 61010; IEC 61326-1
AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 690V
DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 750V
Resistance to: fall from 2m height
Measuring instrument features: AutoTest function; hazardous voltage indicator (>50V AC or 120V DC); low battery indicator; polarization indicator; single-pole voltage testing
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Type of tester: electrical
Continuity test: acoustic indication; optical indication; <100Ω
Bandwidth for AC voltage measurements: 16.66...800Hz
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+5292.33 грн
C.A 742 IP2X
+3
C.A 742 IP2X CHAUVIN ARNOUX CA-762_DS.PDF CA-742_M.PDF Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; VAC: 12V,24V,50V,127V,230V,400V,690V
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: carrying strap; IP2X test probes; test lead
Body dimensions: 163x64x40mm
IP rating: IP65
Kind of display used: LEDs
Weight with battery: 210g
Conform to the norm: CAT IV 600V; EN 61010; IEC 61326-1; NF C 18-510
AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 690V
DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 750V
Resistance to: fall from 2m height
Measuring instrument features: AutoTest function; hazardous voltage indicator (>50V AC or 120V DC); low battery indicator; polarization indicator; single-pole voltage testing
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Type of tester: electrical
Continuity test: acoustic indication; optical indication; <100Ω
Bandwidth for AC voltage measurements: 16.66...800Hz
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+6139.29 грн
C.A 745N
+2
C.A 745N CHAUVIN ARNOUX CA-745N-DS.PDF Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LCD; VAC: 0÷690V; 50/60Hz; VDC: 0÷690V; IP54
Type of tester: electrical
Kind of display used: LCD
AC voltage measuring range: 0...690V
Bandwidth for AC voltage measurements: 50/60Hz
DC voltage measuring range: 0...690V
Continuity test: acoustic indication; optical indication
IP rating: IP54
Conform to the norm: CAT III 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: low battery indicator; polarization indicator; single-pole voltage testing
Standard equipment: test probe x1
Body dimensions: 180x52x45mm
Weight with battery: 200g
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Bargraph: yes
на замовлення 3 шт:
термін постачання 21-30 дні (днів)
1+4528.98 грн
3+ 4148.69 грн
C.A 755
+3
C.A 755 CHAUVIN ARNOUX CA-757_DS.PDF Category: Portable digital multimeters
Description: Digital multimeter; LCD; VDC: 3V,30V,300V,1kV; Test: diodes; IP54
Type of meter: digital multimeter
Measurement: AC voltage; capacitance; continuity; DC voltage; resistance
Kind of display used: LCD
DC voltage measuring range: 3V; 30V; 300V; 1kV
DC voltage measuring accuracy: ±(2% + 3 digit)
AC voltage measuring range: 3V; 30V; 300V; 1kV
AC voltage measuring accuracy: ±(3% + 4 digit)
Resistance measuring range: 300Ω; 3kΩ; 30kΩ; 300kΩ; 3MΩ; 30MΩ
Capacitance measuring range: 3nF; 30nF; 300nF; 3µF; 30µF; 300µF; 3mF; 30mF
Capacitance measuring accuracy: ±(5%+ 5 digit)
Resistance measuring accuracy: ±(3%+3 digit)
Test: diodes
Continuity test: acoustic indication; <30Ω
IP rating: IP54
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: test probes
Conform to the norm: CAT III 600V; EN 61010
Resistance to: fall from 2m height
Dimensions (W x H x D): 180x52x45mm
Measuring instrument features: autoranging; contactless voltage detector; low battery indicator; replaceable measuring tips
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Illumination: yes
товар відсутній
C.A 757
+1
C.A 757 CHAUVIN ARNOUX CA-757_DS.PDF Category: Portable digital multimeters
Description: Digital multimeter; LCD; VDC: 3V,30V,300V,1kV; Test: diodes; IP54
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; continuity; DC voltage; resistance
Kind of display used: LCD
DC voltage measuring range: 3V; 30V; 300V; 1kV
DC voltage measuring accuracy: ±(2% + 3 digit)
AC voltage measuring range: 3V; 30V; 300V; 1kV
AC voltage measuring accuracy: ±(3% + 4 digit)
AC current measuring range: 500mA...30A; 300A
AC current measuring accuracy: ±(3% + 5 digit)
Resistance measuring range: 300Ω; 3kΩ; 30kΩ; 300kΩ; 3MΩ; 30MΩ
Capacitance measuring range: 3nF; 30nF; 300nF; 3µF; 30µF; 300µF; 3mF; 30mF
Capacitance measuring accuracy: ±(5%+ 5 digit)
Resistance measuring accuracy: ±(3%+3 digit)
Test: diodes
Continuity test: acoustic indication; <30Ω
IP rating: IP54
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: probe MiniFlex; test probes; Velcro strap
Conform to the norm: CAT III 600V; EN 61010
Resistance to: fall from 2m height
Dimensions (W x H x D): 180x52x45mm
Measuring instrument features: autoranging; contactless voltage detector; low battery indicator; replaceable measuring tips
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Illumination: yes
товар відсутній
C.A 762
+3
C.A 762 CHAUVIN ARNOUX CA-762_DS.PDF ca-762-m.PDF Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 50÷690VAC; 16.66÷800Hz; IP65
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: carrying strap; test lead; test probe x1
Body dimensions: 163x64x40mm
IP rating: IP65
Kind of display used: LEDs
Weight with battery: 210g
Conform to the norm: CAT IV 600V; EN 61010; IEC 61326-1
AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 690V
DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 750V
Resistance to: fall from 2m height
Measuring instrument features: AutoTest function; hazardous voltage indicator (>50V AC or 120V DC); low battery indicator; polarization indicator; single-pole voltage testing
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Type of tester: electrical
Continuity test: acoustic indication; optical indication; 100Ω...2kΩ; 2kΩ...60kΩ; 60kΩ...300kΩ
Phase-to-phase voltage range for phase sequence indication: 50...690V AC
Bandwidth for AC voltage measurements: 16.66...800Hz
товар відсутній
C.A 762 IP2X
+3
C.A 762 IP2X CHAUVIN ARNOUX CA-762_DS.PDF ca-762-m.PDF Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 50÷690VAC; 16.66÷800Hz; IP65
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: carrying strap; IP2X test probes; test lead
Body dimensions: 163x64x40mm
IP rating: IP65
Kind of display used: LEDs
Weight with battery: 210g
Conform to the norm: CAT IV 600V; EN 61010; IEC 61326-1; NF C 18-510
AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 690V
DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 750V
Resistance to: fall from 2m height
Measuring instrument features: AutoTest function; hazardous voltage indicator (>50V AC or 120V DC); low battery indicator; polarization indicator; single-pole voltage testing
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Type of tester: electrical
Continuity test: acoustic indication; optical indication; 100Ω...2kΩ; 2kΩ...60kΩ; 60kΩ...300kΩ
Phase-to-phase voltage range for phase sequence indication: 50...690V AC
Bandwidth for AC voltage measurements: 16.66...800Hz
товар відсутній
C.A 771
+2
C.A 771 CHAUVIN ARNOUX CA-771-DS.PDF Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 50÷1000VAC; 40÷65Hz; IP65; RCD test: 30mA
Power supply: battery LR6 AA 1,5V x2
Standard equipment: test probe x1; Velcro strap
Body dimensions: 228x60x39mm
IP rating: IP65
Kind of display used: LEDs
Weight with battery: 350g
Conform to the norm: CAT IV 1000V; EN 61010; EN 61243-3; IEC 61326-1
AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV
DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV; 1.4kV
Resistance to: fall from 2m height
Measuring instrument features: AutoTest function; phase sequence indication; polarization indicator; single-pole voltage testing
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Type of tester: electrical
Additional functions: torch
Continuity test: acoustic indication; optical indication
Phase-to-phase voltage range for phase sequence indication: 50...1000V AC
RCD test: 30mA
Bandwidth for AC voltage measurements: 40...65Hz
товар відсутній
C.A 771 IP2X
+2
C.A 771 IP2X CHAUVIN ARNOUX CA-771-DS.PDF Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 50÷1000VAC; 40÷65Hz; IP65; RCD test: 30mA
Power supply: battery LR6 AA 1,5V x2
Standard equipment: IP2X test probes; Velcro strap
Body dimensions: 228x60x39mm
IP rating: IP65
Kind of display used: LEDs
Weight with battery: 350g
Conform to the norm: CAT IV 1000V; EN 61010; EN 61243-3; IEC 61326-1; NF C 18-510
AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV
DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV; 1.4kV
Resistance to: fall from 2m height
Measuring instrument features: AutoTest function; phase sequence indication; polarization indicator; single-pole voltage testing
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Type of tester: electrical
Additional functions: torch
Continuity test: acoustic indication; optical indication
Phase-to-phase voltage range for phase sequence indication: 50...1000V AC
RCD test: 30mA
Bandwidth for AC voltage measurements: 40...65Hz
товар відсутній
C.A 773
+2
C.A 773 CHAUVIN ARNOUX CA-771-DS.PDF Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 50÷1000VAC; 40÷65Hz; IP65
Power supply: battery LR6 AA 1,5V x2
Standard equipment: test probe x1; Velcro strap
Body dimensions: 228x60x39mm
IP rating: IP65
Kind of display used: LCD; LEDs
Weight with battery: 350g
Conform to the norm: CAT IV 1000V; EN 61010; IEC 61326-1
AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV
DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV; 1.4kV
Resistance to: fall from 2m height
Measuring instrument features: AutoTest function; low battery indicator; phase sequence indication; polarization indicator; single-pole voltage testing
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Illumination: yes
Type of tester: electrical
Additional functions: torch
Continuity test: acoustic indication; optical indication
Phase-to-phase voltage range for phase sequence indication: 50...1000V AC
RCD test: 30mA
Bandwidth for AC voltage measurements: 40...65Hz
товар відсутній
C.A 773 IP2X
+2
C.A 773 IP2X CHAUVIN ARNOUX CA-771-DS.PDF Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 50÷1000VAC; 40÷65Hz; IP65
Power supply: battery LR6 AA 1,5V x2
Standard equipment: IP2X test probes; Velcro strap
Body dimensions: 228x60x39mm
IP rating: IP65
Kind of display used: LCD; LEDs
Weight with battery: 350g
Conform to the norm: CAT IV 1000V; EN 61010; IEC 61326-1; NF C 18-510
AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV
DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV; 1.4kV
Resistance to: fall from 2m height
Measuring instrument features: AutoTest function; low battery indicator; phase sequence indication; polarization indicator; single-pole voltage testing
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Illumination: yes
Type of tester: electrical
Additional functions: 17 step speed regulation; torch
Continuity test: acoustic indication; optical indication
Phase-to-phase voltage range for phase sequence indication: 50...1000V AC
RCD test: 30mA
Bandwidth for AC voltage measurements: 40...65Hz
товар відсутній
C.A 8220 C.A 8220 CHAUVIN ARNOUX CA-8220_DS.PDF CA-8220_M.PDF Category: Power Quality Analyzers
Description: Meter: power quality analyser; LCD; VAC: 6÷600V; True RMS; 40÷70Hz
Type of meter: power quality analyser
Measurement: AC current (with current clamps); active power; AC voltage; apparent power; DC current (with current clamps); Displacement Power Factor (DPF); frequency; harmonics; inrush current; power factor; reactive power; resistance; rpm velocity; temperature (option)
Kind of display used: LCD
AC voltage measuring range: 6...600V
True effective value measurement: True RMS
Frequency measuring range: 40...70Hz
Continuity test: acoustic indication
Pollution degree: 2
IP rating: IP54
Dimensions: 211x108x60mm
Weight with battery: 880g
Power supply: battery LR6 AA 1,5V x6
Standard equipment: 2 crocodile clips; optical cable with USB; test leads ( 2pcs.); test probes
Optional equipment: CA-1711 techometr probe
Conform to the norm: CAT III 600V; EN 61010
Measuring instrument features: automatic power-off; automatic recognition various current detectors; datalogging; indicates phase sequence
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: Power Analyser Transfer
Illumination: yes
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
1+60772.73 грн
C.A 8336 C.A 8336 CHAUVIN ARNOUX CA-8336_DS.PDF Category: Power Quality Analyzers
Description: Meter: power quality analyser; colour,LCD TFT; Interface: USB
IP rating: IP53
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; IEC 61000-4-30
Kind of network: three-phase
Interface: USB
Display resolution: 320x240
Dimensions: 240x180x55mm
Standard equipment: 12-colour set to mark leads and inputs; aligator clip x5; carrying case; mains cable; manual (CD); screen protector preventing scratching (set); test leads ( 5pcs.); USB cable
Measuring instrument features: automatic recognition various current detectors; more than 450 recordable values with the required parameters and graphic displays; operation of several modes in parallel; possibility of viewing the data during a campaign; up to 40 alarms can be set simultaneously
Type of meter: power quality analyser
Producer guarantee (months): 36
Measurement: AC current (with current clamps); active power; AC voltage; apparent power; DC current (option); DC voltage; distorting power; energy; harmonics; inrush current; K factor for transformers; reactive power; short or long-term flicker
Software: Power Analyser Transfer
Kind of display used: colour; LCD TFT
Number of inputs: 9
Power supply: rechargeable battery Ni-MH x1
Supply voltage: 100...240V AC
товар відсутній
C.A 850
+4
C.A 850 CHAUVIN ARNOUX Category: Manometers and Pressure Meters
Description: Manometer; -100÷100psi; LCD; Meas.accur: ±0,3%; 0÷50°C
Type of meter: manometer
Pressure measuring range: -100...100psi
Kind of display used: LCD
Measurement accuracy: ±0,3%
Dimensions: 72x182x30mm
Power supply: battery 6LR61 9V x1
Measuring instrument features: AUTO HOLD; automatic power-off; differential pressure measurements; logging of MAX, MIN
Standard equipment: 2 connection tubes; soft case; user's manual
Measurement: pressure
Measuring unit: bar; cm H2O; ft H2O; in Hg; in H2O; kg/cm2; kPa; mm Hg; ozin2
Operating temperature: 0...50°C
Measuring resolution: 0,01 psi
Battery/ rechargeable battery: battery 6LR61 9V x1
Illumination: yes
товар відсутній
C.A 1110 C.A 1110 CHAUVIN ARNOUX CA-1110_DS.PDF Category: Luxmeters
Description: Light meter; 0,1÷200000lx; 3%; Bluetooth,USB; -10÷60°C; IP50
Type of meter: light meter
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MAP mode; MIN/MAX/MEDIUM function
Operating temperature: -10...60°C
Conform to the norm: IEC 61010-1; IEC 61326-1
Power supply: battery LR6 AA 1,5V x3
Dimensions: 150x72x32mm
Standard equipment: case; USB cable
Kind of measured light: fluorescent; LED; standard
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Kind of display used: LCD
IP rating: IP50
Interface: Bluetooth; USB
Measurement accuracy: 3%
Resistance to: fall from 1m height
Illumination: yes
Measurement memory: 1000000
Measuring range: 0,1...200000lx
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
1+32930.1 грн
3+ 31597.26 грн
C.A 1246
+1
C.A 1246 CHAUVIN ARNOUX CA-1246_DS.PDF Category: Thermohygrometers
Description: Thermo-hygrometer; LCD; -10÷60°C; 3÷98%RH; ±(0.5%+1digit); 0.1°C
Type of meter: thermo-hygrometer
Measurement: dew point; humidity; temperature
Measuring instrument features: automatic power-off; data logger function; HOLD function; MIN/MAX function; programmable alarm thresholds
Conform to the norm: IEC 61010-1; IEC 61326-1
Power supply: battery LR6 AA 1,5V x3
Dimensions: 187x72x32mm
Standard equipment: case; USB cable
Temperature measurement resolution: 0.1°C
Temperature measuring range: -10...60°C
Humidity measuring range: 3...98% RH
Dew-point measurement: -10...60°C
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Temperature measurement accuracy: ±(0.5% + 1 digit)
Kind of display used: LCD
IP rating: IP54
Interface: Bluetooth; USB
Illumination: yes
Measurement memory: 1000000
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
1+25603.84 грн
C.A 1510 CHAUVIN ARNOUX Category: Gas Meters and Loggers
Description: Meter: CO2, temperature and humidity; Range: 0÷5000ppm,5÷95%
Kind of display used: LCD
Body dimensions: 125x65.5x32mm
IP rating: IP40
Temperature measuring range: -10...60°C
Measurement accuracy: ± (50 ppm + 3% of the value measured)
Standard equipment: USB adapter; USB/USB Micro cable; user's manual
Measuring instrument features: alarm activated on limit values exceeding
Type of meter: CO2, temperature and humidity
Humidity measuring accuracy: ±2% RH
Measuring resolution: 0,1%; 0,1°C; 1ppm
Event memory: 1M
Measurement: CO2; humidity; temperature
Software: compatible Android; compatible Windows 7; compatible Windows 8.1; compatible Windows 10; Data Logger Transfer
Temperature measurement accuracy: ±0.5°C
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth; USB
Illumination: yes
Measuring range: 0...5000ppm; 5...95%
кількість в упаковці: 1 шт
товар відсутній
C.A 1631 CHAUVIN ARNOUX Category: Calibrators
Description: Meter: calibrator; voltage,current; VDC: 0÷100mV,10V; I DC: 0÷24mA
Type of meter: calibrator
Measurement: DC current; DC voltage
Measuring instrument features: 24V loop supply voltage
Power supply: battery GR03 AAA 1,5V x6
Dimensions: 205x97x45mm
Standard equipment: case; insulated crocodile clips; set of test leads with probes
Kind of calibrator: current; voltage
DC current measuring range: 0...24mA
DC voltage measuring range: 0...100mV; 10V
Battery/ rechargeable battery: battery GR03 AAA 1,5V x6
Current source: 0...24mA
Voltage source: 0...100mV; 0...20V
DC voltage measuring accuracy: ±(0.02% + 3 digit)
DC current measuring accuracy: ±(0.015% + 3 digit)
Kind of display used: LCD
Illumination: yes
кількість в упаковці: 1 шт
товар відсутній
C.A 1821
+1
C.A 1821 CHAUVIN ARNOUX CA-1820-DS.PDF CA-1820-INS.PDF Category: Temperature and Humidity Loggers
Description: Data logger; temperature; ±(0.2%+0.6°C); Temp: -250÷1767°C; IP54
Type of meter: data logger
Measurement: temperature
Temperature measurement accuracy: ±(0.2% + 0.6°C)
Power supply: battery LR6 AA 1,5V x3
Standard equipment: case; USB cable
Temperature measuring range: -250...1767°C
Interface: Bluetooth; USB
IP rating: IP54
Kind of display used: LCD
Dimensions: 150x72x32mm
Kind of temperature sensor: thermocouple E; thermocouple J; thermocouple K; thermocouple N; thermocouple R; thermocouple S; thermocouple T
Operating temperature: -10...60°C
Number of channels: 1
Temperature measuring range (with K-type thermocouple): -200...1372°C
Temperature measuring range (with J-type thermocouple): -210...1200°C
Temperature measuring range (with T-type thermocouple): -250...400°C
Temperature measuring range with N-type thermocouple: -200...1300°C
Temperature measuring range (with R-type thermocouple): 0...1767°C
Temperature measuring range (with S-type thermocouple): 0...1767°C
Temperature measuring range (with E-type thermocouple): -150...950°C
Producer guarantee (months): 24
Measuring instrument features: automatic power-off; HOLD function; long operating time up to 3 years (at 15-minute measurement interval); MIN/MAX function; programmable alarm thresholds
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Measurement memory: 100000
Software: dedicated mobile app
Supported formats: EXCEL
Illumination: yes
кількість в упаковці: 1 шт
товар відсутній
C.A 1822
+7
C.A 1822 CHAUVIN ARNOUX CA-1820-DS.PDF CA-1820-INS.PDF Category: Temperature and Humidity Loggers
Description: Data logger; differential temperature,temperature; IP54; Ch: 2
Type of meter: data logger
Measurement: differential temperature; temperature
Temperature measurement accuracy: ±(0.2% + 0.6°C)
Power supply: battery LR6 AA 1,5V x3
Standard equipment: case; USB cable
Temperature measuring range: -250...1767°C
Interface: Bluetooth; USB
IP rating: IP54
Kind of display used: LCD
Dimensions: 150x72x32mm
Kind of temperature sensor: thermocouple E; thermocouple J; thermocouple K; thermocouple N; thermocouple R; thermocouple S; thermocouple T
Operating temperature: -10...60°C
Number of channels: 2
Temperature measuring range (with K-type thermocouple): -200...1372°C
Temperature measuring range (with J-type thermocouple): -210...1200°C
Temperature measuring range (with T-type thermocouple): -250...400°C
Temperature measuring range with N-type thermocouple: -200...1300°C
Temperature measuring range (with R-type thermocouple): 0...1767°C
Temperature measuring range (with S-type thermocouple): 0...1767°C
Temperature measuring range (with E-type thermocouple): -150...950°C
Producer guarantee (months): 24
Measuring instrument features: automatic power-off; HOLD function; long operating time up to 3 years (at 15-minute measurement interval); MIN/MAX function; programmable alarm thresholds
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Measurement memory: 100000
Software: dedicated mobile app
Supported formats: EXCEL
Illumination: yes
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
1+22858.58 грн
3+ 21360.47 грн
C.A 1823
+1
C.A 1823 CHAUVIN ARNOUX CA-1820-DS.PDF CA-1820-INS.PDF Category: Temperature and Humidity Loggers
Description: Data logger; temperature; ±(0.4%+0.3°C); Temp: -100÷400°C; IP54
Type of meter: data logger
Measurement: temperature
Temperature measurement accuracy: ±(0.4% + 0.3°C)
Power supply: battery LR6 AA 1,5V x3
Standard equipment: case; USB cable
Temperature measuring range: -100...400°C
Interface: Bluetooth; USB
IP rating: IP54
Kind of display used: LCD
Dimensions: 150x72x32mm
Kind of temperature sensor: Pt100; Pt1000
Operating temperature: -10...60°C
Number of channels: 1
Producer guarantee (months): 24
Measuring instrument features: automatic power-off; HOLD function; long operating time up to 3 years (at 15-minute measurement interval); MIN/MAX function; programmable alarm thresholds
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Measurement memory: 100000
Software: dedicated mobile app
Supported formats: EXCEL
Illumination: yes
кількість в упаковці: 1 шт
товар відсутній
C.A 1866 CHAUVIN ARNOUX Category: Pirometers
Description: Infrared thermometer; LCD; -50÷1000°C; Accur: ±2°C; ±1.5%; ε: 0,1÷1
Type of meter: infrared thermometer
Kind of display used: LCD
Non-contact temperature measuring range: -50...1000°C
Temperature measurement accuracy: ±1.5%; ±2°C
Non-contact temperature measuring resolution: 0.1°C
Optical resolution: 50:1
Emissivity value: 0,1...1
Measurement: non-contact temeprature (IR)
Measuring unit: °C; °F
Dimensions: 230x100x56mm
Power supply: battery 9V x1
Measuring instrument features: adjustable emissivity; automatic power-off; HOLD function; laser sight; low battery indicator; MIN/MAX/MEDIUM function
Battery/ rechargeable battery: battery 9V x1
Illumination: yes
кількість в упаковці: 1 шт
товар відсутній
C.A 1950 P01651901
+6
C.A 1950 P01651901 CHAUVIN ARNOUX CA-1950_DS.PDF CA-1950_M.PDF Category: Infrared Cameras - Others
Description: Infrared camera; LCD 2,8"; 80x80; 9Hz; -20÷250°C; Focus: automatic
Type of meter: infrared camera
Kind of display used: LCD 2,8"
Camera resolution: 80x80
Refresh rate: 9Hz
Temperature measuring range: -20...250°C
Temperature measurement accuracy: ±2%; ±2°C
Focusing: automatic
IP rating: IP54
Body dimensions: 225x125x83mm
Weight with battery: 700g
Power supply: rechargeable battery Ni-MH x4
Measuring instrument features: Bluetooth communication with clamp meters and multimeters; socket for mounting on a stand; temperature markers (min, max); thermal or real image; voice annotation
Standard equipment: Bluetooth earphones; hard case; mains battery charger; microSDHC memory card; USB cable; user's manual
Thermal sensitivity (NETD): ≤0.08 @ 30°C
Three-dimensional resolution: 4.4mrad
Emissivity value: 0,05...1
Interface: Bluetooth; USB
Resistance to: fall from 2m height
Related items: CA-F407; CA-F607
Battery/ rechargeable battery: rechargeable battery Ni-MH x4
Software: included
Field of observation: 20° horizontal x 20° vertical
кількість в упаковці: 1 шт
товар відсутній
C.A 1954 P01651904
+6
C.A 1954 P01651904 CHAUVIN ARNOUX HLHBEMGI.PDF CA-1954-INS.PDF Category: Infrared Cameras - Others
Description: Infrared camera; LCD 2,8"; 160x120; 9Hz; -20÷250°C; IP54; 4.1mrad
Type of meter: infrared camera
Kind of display used: LCD 2,8"
Camera resolution: 160x120
Refresh rate: 9Hz
Temperature measuring range: -20...250°C
Temperature measurement accuracy: ±2%; ±2°C
Focusing: focus free
IP rating: IP54
Body dimensions: 225x125x83mm
Weight with battery: 700g
Power supply: rechargeable battery Ni-MH x4
Measuring instrument features: Bluetooth communication with clamp meters and multimeters; socket for mounting on a stand; temperature markers (min, max); thermal or real image; voice annotation
Standard equipment: Bluetooth earphones; hard case; mains battery charger; microSDHC memory card; USB cable; user's manual
Thermal sensitivity (NETD): ≤0.08 @ 30°C
Three-dimensional resolution: 4.1mrad
Emissivity value: 0,05...1
Interface: Bluetooth; USB
Resistance to: fall from 2m height
Related items: CA-F407; CA-F607
Battery/ rechargeable battery: rechargeable battery Ni-MH x4
Software: included
Field of observation: 38° horizontal x 28° vertical
кількість в упаковці: 1 шт
товар відсутній
C.A 5001
+3
C.A 5001 CHAUVIN ARNOUX CA-5000-DS.PDF CA-5001-INS.PDF Category: Analog Multimeters
Description: Analogue multimeter; Features: blown fuse indicator; IP40
Type of meter: analogue multimeter
Measuring instrument features: blown fuse indicator
DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV
DC voltage measuring accuracy: ±1.5%
AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV
AC voltage measuring accuracy: ±2.5%
AC current measuring range: 5mA; 50mA; 0.5A; 5A
DC current measuring range: 50µA; 5mA; 50mA; 500mA; 5A
DC current measuring accuracy: ±2.5%
AC current measuring accuracy: ±2.5%
Resistance measuring range: 5...1MΩ
Resistance measuring accuracy: ±10%
Continuity test: acoustic indication; <50Ω
Power supply: battery LR6 AA 1,5V x1
Standard equipment: test leads; test probes
Measurement: AC current; AC voltage; DC current; DC voltage; resistance
Conform to the norm: CAT III 600V; EN 61010
Body dimensions: 56x105x160mm
Battery/ rechargeable battery: battery LR6 AA 1,5V x1
IP rating: IP40
Input impedance for AC voltage: 6.32kΩ/V
Input impedance for DC voltage measurement: 20kΩ/V
Producer guarantee (months): 36
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
1+22655.12 грн
C.A 5003
+3
C.A 5003 CHAUVIN ARNOUX CA-5000-DS.PDF CA-5003-INS.PDF Category: Analog Multimeters
Description: Analogue multimeter; VDC: 100mV,1V,3V,10V,30V,100V,300V,1kV
Type of meter: analogue multimeter
Measuring instrument features: automatic calibration; blown fuse indicator
DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV
DC voltage measuring accuracy: ±1.5%
AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV
AC voltage measuring accuracy: ±2.5%
AC current measuring range: 1.5mA; 15mA; 150mA; 1.5A; 15A
DC current measuring range: 50µA; 150µA; 1.5mA; 15mA; 150mA; 1.5A; 15A
DC current measuring accuracy: ±2.5%
AC current measuring accuracy: ±2.5%
Resistance measuring range: 5...1MΩ
Resistance measuring accuracy: ±10%
Continuity test: acoustic indication; <50Ω
Power supply: battery 6F22 9V x1
Standard equipment: test leads; test probes
Measurement: AC current; AC voltage; DC current; DC voltage; resistance
Conform to the norm: CAT III 600V; EN 61010
Body dimensions: 56x105x160mm
Battery/ rechargeable battery: battery 6F22 9V x1
IP rating: IP53
Input impedance for AC voltage: 6.32kΩ/V
Input impedance for DC voltage measurement: 20kΩ/V
Producer guarantee (months): 36
кількість в упаковці: 1 шт
на замовлення 2 шт:
термін постачання 7-14 дні (днів)
1+30251.73 грн
C.A 5005 + MN89
+6
C.A 5005 + MN89 CHAUVIN ARNOUX CA-5000-DS.PDF CA-5005-MN89.PDF Category: Analog Multimeters
Description: Analogue multimeter; VDC: 100mV,1V,3V,10V,30V,100V,300V,1kV
Type of meter: analogue multimeter
Measuring instrument features: automatic calibration; blown fuse indicator
DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV
DC voltage measuring accuracy: ±1.5%
AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV
AC voltage measuring accuracy: ±2.5%
AC current measuring range: 3A; 10A; 30A; 100A; 240A
DC current measuring range: 50µA; 1mA; 10mA; 100mA; 1A; 10A
DC current measuring accuracy: ±2.5%
AC current measuring accuracy: ±2.5%
Resistance measuring range: 5...1MΩ
Resistance measuring accuracy: ±10%
Continuity test: acoustic indication; <50Ω
Power supply: battery 6F22 9V x1
Standard equipment: CA-MN89 - current clamp; holster; test leads
Measurement: AC current (with current clamps); AC voltage; DC current; DC voltage; resistance
Conform to the norm: CAT III 600V; EN 61010
Body dimensions: 56x105x160mm
IP rating: IP53
Input impedance for AC voltage: 6.32kΩ/V
Input impedance for DC voltage measurement: 20kΩ/V
Producer guarantee (months): 36
кількість в упаковці: 1 шт
товар відсутній
C.A 5011
+4
C.A 5011 CHAUVIN ARNOUX ca-5011-dte.PDF ca-5011-ins.PDF Category: Analog Multimeters
Description: Analogue multimeter; analogue,LCD; (4000); Test: diodes; IP53
Type of meter: analogue multimeter
Measuring instrument features: HOLD function; impact resistant holster; MAX function
Kind of display used: analogue; LCD
Display parameters: (4000)
DC voltage measuring range: 400mV; 4V; 40V; 400V; 1kV
DC voltage measuring accuracy: ±(1% + 2 digits)
AC voltage measuring range: 400mV; 4V; 40V; 400V; 1kV
AC voltage measuring accuracy: ±(1,5% + 5 digits)
DC current measuring range: 0.4mA; 4mA; 40mA; 400mA; 1A; 10A
AC current measuring range: 0.4mA; 4mA; 40mA; 400mA; 1A; 10A
DC current measuring accuracy: ±(1,5% + 2 digits)
AC current measuring accuracy: ±(2% + 5 digits)
Resistance measuring accuracy: ±(1% + 2 digits)
Test: diodes
Continuity test: acoustic indication; <400Ω
Power supply: battery 6F22 9V x1
Standard equipment: test leads; test probes
Measurement: AC current; AC voltage; DC current; DC voltage; resistance
Conform to the norm: CAT III 600V; EN 61010
Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 40MΩ
Body dimensions: 56x105x160mm
IP rating: IP53
Producer guarantee (months): 36
Frequency measuring range: 4kHz; 40kHz; 100kHz
True effective value measurement: True RMS
Battery/ rechargeable battery: battery 6F22 9V x1
Alias: P01196311E
Illumination: yes
кількість в упаковці: 1 шт
товар відсутній
C.A 5231
+3
C.A 5231 CHAUVIN ARNOUX CA-5231-M.PDF Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 3x/s; True RMS
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
IP rating: IP54
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Resistance to: fall from 1m height
Illumination: yes
Standard equipment: test leads
Measuring instrument features: auto and manual ranging; automatic power-off; contactless voltage detector; HOLD function; low battery indicator; low input impedance function (LoZ)
Type of meter: digital multimeter
Test: diodes
Continuity test: acoustic indication
Sampling: 3x/s
True effective value measurement: True RMS
Bargraph: 61 segm.
Producer guarantee (months): 12
Measurement: AC current (with current clamps); AC voltage; continuity; DC current (with current clamps); DC voltage; resistance
Dimensions (W x H x D): 75x155x75mm
Bandwidth for AC voltage measurements: 45...60Hz; 60Hz...1kHz
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ
DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: (6000)
DC voltage measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(0.3%+4 digit)
кількість в упаковці: 1 шт
на замовлення 2 шт:
термін постачання 7-14 дні (днів)
1+13414.14 грн
3+ 12765.75 грн
C.A 5231 KIT
+4
C.A 5231 KIT CHAUVIN ARNOUX Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 3x/s; True RMS
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
IP rating: IP54
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Resistance to: fall from 1m height
Illumination: yes
Standard equipment: CA-MINI-03 - current clamp; test leads
Measuring instrument features: auto and manual ranging; automatic power-off; contactless voltage detector; HOLD function; low battery indicator; low input impedance function (LoZ)
Type of meter: digital multimeter
Test: diodes
Continuity test: acoustic indication
Sampling: 3x/s
True effective value measurement: True RMS
Bargraph: 61 segm.
Producer guarantee (months): 12
Measurement: AC current (with current clamps); AC voltage; continuity; DC current (with current clamps); DC voltage; resistance
Dimensions (W x H x D): 75x155x75mm
Bandwidth for AC voltage measurements: 45...60Hz; 60Hz...1kHz
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ
DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: (6000)
DC voltage measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(0.3%+4 digit)
кількість в упаковці: 1 шт
товар відсутній
C.A 5233
+4
C.A 5233 CHAUVIN ARNOUX CA-5233-M.PDF Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 3x/s; True RMS
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Kind of display used: LCD
Display parameters: (6000)
Bargraph: 61 segm.
Sampling: 3x/s
DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(2% + 3 digit)
Bandwidth for AC voltage measurements: 45...60Hz; 60Hz...1kHz
DC current measuring range: 6A; 10A; 15A < 60s
DC current measuring accuracy: ±(1.5% + 3 digit)
AC current measuring range: 6A; 10A; (15A <60s)
AC current measuring accuracy: ±(2% + 3 digit)
Bandwidth for AC current measurements: 40Hz...1kHz
True effective value measurement: True RMS
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ
Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 1mF
Capacitance measuring accuracy: ±(3.5%+ 4 digit)
Frequency measuring range: 10...3000Hz
Frequency measuring accuracy: ±0.5%
Temperature measurement accuracy: ±(2% + 5°C)
Temperature measuring range (with K-type thermocouple): -20...760°C
Resistance measuring accuracy: ±(0.3%+4 digit)
Duty cycle factor: 0.1...99.9%
Test: diodes
Continuity test: acoustic indication
IP rating: IP54
Power supply: battery 6LR61 9V x1
Standard equipment: banana plug - K plug adapter; drop-like K-type temperature probe; test leads
Conform to the norm: CAT III 600V; CAT IV 600V; EN 61010
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Resistance to: fall from 1m height
Dimensions (W x H x D): 75x155x75mm
Producer guarantee (months): 12
Measuring instrument features: auto and manual ranging; automatic power-off; contactless voltage detector; HOLD function; low battery indicator; low input impedance function (LoZ); MIN/MAX/REL function
Battery/ rechargeable battery: battery 6LR61 9V x1
Illumination: yes
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
1+16462.27 грн
3+ 15625.28 грн
C.A 5273 C.A 5273 CHAUVIN ARNOUX CA-5273_DS.PDF CA-5273_M.PDF Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 5x/s; True RMS
Type of meter: digital multimeter
Measuring instrument features: auto and manual ranging; automatic calibration; automatic power-off; HOLD function; low input impedance function (LoZ); low-pass filter; MIN/MAX function
Kind of display used: LCD
Bargraph: 61 segm.
Sampling: 5x/s
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1.2% + 3 digit)
Bandwidth for AC voltage measurements: 40...400Hz; 400Hz...3kHz
AC current measuring range: 6A; 10A
DC current measuring range: 6A; 10A; 20A < 30s
DC current measuring accuracy: ±(0.8% + 2 digit)
AC current measuring accuracy: ±(1% + 3 digit)
Bandwidth for AC current measurements: 40Hz...1kHz
True effective value measurement: True RMS
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ
Resistance measuring accuracy: ±(1%+2 digit)
Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF
Capacitance measuring accuracy: ±(1%+ 5 digit)
Frequency measuring range: 100mHz...600Hz; 6kHz; 60kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
Temperature measurement accuracy: ±(0.5% + 2°C)
Test: diodes
Continuity test: acoustic indication
Power supply: battery 6F22 9V x1
Standard equipment: drop-like K-type temperature probe; test leads; test probes
Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Temperature measuring range (with K-type thermocouple): -59.6...1200°C
Dimensions (W x H x D): 90x190x45mm
Display parameters: (6000)
Illumination: yes
Battery/ rechargeable battery: battery 6F22 9V x1
IP rating: IP54
Resistance to: fall from 1m height
Producer guarantee (months): 36
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
1+23766.24 грн
C.A 5275
+5
C.A 5275 CHAUVIN ARNOUX CA-5273_DS.PDF CA-5275-M.PDF Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 5x/s; True RMS
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
IP rating: IP54
Power supply: battery 6F22 9V x1
Kind of display used: LCD
Resistance to: fall from 1m height
Illumination: yes
Standard equipment: case; MultiFIX mounting system; test leads; test probes
Measuring instrument features: auto and manual ranging; automatic calibration; automatic power-off; HOLD function; ionization current measurement; low input impedance function (LoZ); low-pass filter; MIN/MAX function; selection of AC or AC+DC measurement
Type of meter: digital multimeter
Test: diodes
Continuity test: acoustic indication
Sampling: 5x/s
True effective value measurement: True RMS
Bargraph: 61 segm.
Producer guarantee (months): 36
Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 90x190x45mm
Bandwidth for AC voltage measurements: 40...400Hz; 400Hz...10kHz
AC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; (20A <30s)
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ
Bandwidth for AC current measurements: 40Hz...1kHz
DC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 100mHz...600Hz; 6kHz; 60kHz
Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF
Battery/ rechargeable battery: battery 6F22 9V x1
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
AC current measuring accuracy: ±(1% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.8% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(1%+2 digit)
кількість в упаковці: 1 шт
на замовлення 3 шт:
термін постачання 7-14 дні (днів)
1+27889.23 грн
3+ 26297.45 грн
C.A 5277
+6
C.A 5277 CHAUVIN ARNOUX CA-5273_DS.PDF CA-5277-M.PDF Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 5x/s; True RMS
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
Temperature measuring range (with K-type thermocouple): -59.6...1200°C
Temperature measurement accuracy: ±(0.5% + 2°C)
Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance; temperature
Sampling: 5x/s
Resistance to: fall from 1m height
Power supply: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
IP rating: IP54
Producer guarantee (months): 36
Measuring instrument features: auto and manual ranging; automatic calibration; automatic power-off; HOLD function; ionization current measurement; low input impedance function (LoZ); low-pass filter; MIN/MAX/DIF/AVG function; MIN/MAX function; PEAK function; selection of AC or AC+DC measurement
Standard equipment: case; drop-like K-type temperature probe; MultiFIX mounting system; test leads; test probes
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Battery/ rechargeable battery: battery 6F22 9V x1
Illumination: yes
Capacitance measuring accuracy: ±(1%+ 5 digit)
Test: diodes
Continuity test: acoustic indication
True effective value measurement: True RMS
Bargraph: 61 segm.
Dimensions (W x H x D): 90x190x45mm
Bandwidth for AC voltage measurements: 40...400Hz; 400Hz...10kHz
AC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; (20A <30s)
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ
Bandwidth for AC current measurements: 40Hz...1kHz
DC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 100mHz...600Hz; 6kHz; 60kHz
Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF
Frequency measuring accuracy: ±(0.1%+2 digit)
AC current measuring accuracy: ±(1% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.8% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(1%+2 digit)
кількість в упаковці: 1 шт
на замовлення 2 шт:
термін постачання 7-14 дні (днів)
1+29961.88 грн
3+ 28621.27 грн
C.A 5292 C.A 5292 CHAUVIN ARNOUX CA-5293.PDF Category: Portable digital multimeters
Description: Digital multimeter; USB; colour,LCD; (100000); 5x/s; True RMS
Type of meter: digital multimeter
Kind of display used: colour; LCD
Display parameters: (100000)
Temperature measuring range: -200...800°C
Temperature measuring range (with K-type thermocouple): -40...1200°C
Temperature measurement accuracy: ±0.1%
Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Sampling: 5x/s
Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K
Interface: USB
Power supply: rechargeable battery Ni-MH AA 1,2V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
IP rating: IP67
Producer guarantee (months): 36
Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement
Standard equipment: case; mains battery charger; test leads; test probes; USB cable
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4
Software: included
Illumination: yes
Test: diodes
Continuity test: acoustic indication
Event memory: 10000
True effective value measurement: True RMS
Dimensions (W x H x D): 90x169x47.1mm
AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s)
Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s
DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV
AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV
Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz
Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
DC voltage measuring accuracy: ±(0.03% + 8 digit)
DC current measuring accuracy: ±(0.08% + 8 digit)
Resistance measuring accuracy: ±(0.07%+8 digit)
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
1+57729.41 грн
3+ 54917.83 грн
C.A 5292-BT C.A 5292-BT CHAUVIN ARNOUX CA-5293.PDF Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth,USB; colour,LCD; (100000); 5x/s
Type of meter: digital multimeter
Kind of display used: colour; LCD
Display parameters: (100000)
Temperature measuring range: -200...800°C
Temperature measuring range (with K-type thermocouple): -40...1200°C
Temperature measurement accuracy: ±0.1%
Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Sampling: 5x/s
Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K
Interface: Bluetooth; USB
Power supply: rechargeable battery Ni-MH AA 1,2V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
IP rating: IP67
Producer guarantee (months): 36
Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement
Standard equipment: case; mains battery charger; test leads; test probes; USB cable
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4
Software: included
Illumination: yes
Test: diodes
Continuity test: acoustic indication
Event memory: 30000
True effective value measurement: True RMS
Dimensions (W x H x D): 90x169x47.1mm
AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s)
Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s
DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV
AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV
Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz
Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
DC voltage measuring accuracy: ±(0.03% + 8 digit)
DC current measuring accuracy: ±(0.08% + 8 digit)
Resistance measuring accuracy: ±(0.07%+8 digit)
кількість в упаковці: 1 шт
товар відсутній
C.A 5293 C.A 5293 CHAUVIN ARNOUX CA-5293.PDF Category: Portable digital multimeters
Description: Digital multimeter; USB; colour,LCD; (100000); 5x/s; True RMS
Type of meter: digital multimeter
Kind of display used: colour; LCD
Display parameters: (100000)
Temperature measuring range: -200...800°C
Temperature measuring range (with K-type thermocouple): -40...1200°C
Temperature measurement accuracy: ±0.1%
Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Sampling: 5x/s
Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K
Interface: USB
Power supply: rechargeable battery Ni-MH AA 1,2V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
IP rating: IP67
Producer guarantee (months): 36
Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement
Standard equipment: case; mains battery charger; test leads; test probes; USB cable
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4
Software: included
Illumination: yes
Test: diodes
Continuity test: acoustic indication
Event memory: 10000
True effective value measurement: True RMS
Dimensions (W x H x D): 90x169x47.1mm
AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s)
Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s
DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV
AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV
Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz
Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
DC voltage measuring accuracy: ±(0.03% + 8 digit)
DC current measuring accuracy: ±(0.08% + 8 digit)
Resistance measuring accuracy: ±(0.07%+8 digit)
кількість в упаковці: 1 шт
товар відсутній
C.A 5293-BT C.A 5293-BT CHAUVIN ARNOUX CA-5293.PDF Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth,USB; colour,LCD; (100000); 5x/s
Illumination: yes
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Standard equipment: case; mains battery charger; test leads; test probes; USB cable
Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement
Type of meter: digital multimeter
Test: diodes
Continuity test: acoustic indication
Sampling: 5x/s
Temperature measuring range: -200...800°C
Temperature measuring range (with K-type thermocouple): -40...1200°C
Event memory: 30000
True effective value measurement: True RMS
Producer guarantee (months): 36
Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Dimensions (W x H x D): 90x169x47.1mm
AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s)
Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s
DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV
AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV
Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz
Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4
Software: included
Display parameters: (100000)
DC voltage measuring accuracy: ±(0.02% + 8 digit)
DC current measuring accuracy: ±(0.08% + 8 digit)
Resistance measuring accuracy: ±(0.07%+8 digit)
Temperature measurement accuracy: ±0.1%
Kind of display used: colour; LCD
Power supply: rechargeable battery Ni-MH AA 1,2V x4
IP rating: IP67
Interface: Bluetooth; USB
Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
кількість в упаковці: 1 шт
на замовлення 3 шт:
термін постачання 7-14 дні (днів)
1+70370.61 грн
3+ 66866.57 грн
C.A 6113 CHAUVIN ARNOUX CA-6116N_DS.PDF Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD 5,7"; 320x240; IP53; Illumin: yes
IP rating: IP53
Measuring instrument features: long operating time up to 24 hours; programmable alarm thresholds; test leads resistance compensation
Power supply: rechargeable battery Ni-MH x1
Standard equipment: 3 crocodile clips; carrying case; hand strap; mains battery charger; neckstrap; remote probe; screen protector preventing scratching (set); test leads; test probes
Optional equipment: CA-C177; CA-C177A; CA-MN77
Loop impedance measuring accuracy: ±(5% + 2 digits)
Body dimensions: 280x190x128mm
Kind of display used: LCD 5,7"
Continuity test: acoustic indication; optical indication
Earthing resistance measuring accuracy: ±(2% + 2 digits)
Display resolution: 320x240
Weight with battery: 2.2kg
Loop impedance measurement: 100...500mΩ; 4Ω; 40Ω; 400Ω
Alias: P01145445
RCD test: AC, A and F-type RCDs; general purpose
Insulation resistance measuring ranges: 0.01MΩ...2GΩ
Test voltage: 50V; 100V; 250V; 500V; 1kV
Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010; IEC 61326-1
Illumination: yes
Type of meter: appliance meter
Measurement: AC current (with current clamps); AC voltage; continuity; DC voltage; earthing resistance; frequency; impedance; insulation resistance; leakage current; phase sequence; RCD tripping current; RCD tripping time; short circuit loop impedance; votlage drop
Earthing resistance measuring range: 500mΩ...40Ω; 15kΩ; 40kΩ
Battery/ rechargeable battery: rechargeable battery Ni-MH x1
кількість в упаковці: 1 шт
товар відсутній
C.A 6116N C.A 6116N CHAUVIN ARNOUX CA-6116N_DS.PDF CA-6116N_M.PDF Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; colour,LCD 5,7"; 320x240; USB; IP53
Type of meter: appliance meter
Interface: USB
Measurement: AC current (with current clamps); active power; AC voltage; continuity; DC voltage; earthing resistance; frequency; harmonics; impedance; insulation resistance; leakage current; phase sequence; RCD tripping current; RCD tripping time; short circuit loop impedance; votlage drop
Kind of display used: colour; LCD 5,7"
Display resolution: 320x240
Continuity test: acoustic indication; optical indication
IP rating: IP53
Body dimensions: 280x190x128mm
Weight with battery: 2.2kg
Power supply: rechargeable battery Li-Ion 10,8V x1
Standard equipment: 3 crocodile clips; carrying case; hand strap; mains battery charger; neckstrap; remote probe; screen protector preventing scratching (set); test leads; test probes; USB cable
Optional equipment: CA-C177A; CA-MN77
Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010; IEC 61326-1
Measuring instrument features: long operating time up to 30 hours; programmable alarm thresholds; test leads resistance compensation
Test voltage: 50V; 100V; 250V; 500V; 1kV
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: included
Insulation resistance measuring ranges: 0.01MΩ...2GΩ
Illumination: yes
Earthing resistance measuring range: 500mΩ...40Ω; 15kΩ; 40kΩ
Loop impedance measuring accuracy: ±(5% + 2 digit)
Earthing resistance measuring accuracy: ±(2% + 2 digit)
RCD test: AC, A and F-type RCDs; general purpose
Loop impedance measurement: 100...500mΩ; 4Ω; 40Ω; 400Ω
кількість в упаковці: 1 шт
на замовлення 2 шт:
термін постачання 7-14 дні (днів)
1+139701.64 грн
C.A 6117
+3
C.A 6117 CHAUVIN ARNOUX CA-6116N_DS.PDF CA-6116N_M.PDF Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; colour,LCD 5,7"; 320x240; USB; IP53
Type of meter: appliance meter
Interface: USB
Measurement: AC current (with current clamps); active power; AC voltage; continuity; DC voltage; earthing resistance; frequency; harmonics; impedance; insulation resistance; leakage current; phase sequence; RCD tripping current; RCD tripping time; short circuit loop impedance; votlage drop
Kind of display used: colour; LCD 5,7"
Display resolution: 320x240
Continuity test: acoustic indication; optical indication
IP rating: IP53
Body dimensions: 280x190x128mm
Weight with battery: 2.2kg
Power supply: rechargeable battery Li-Ion 10,8V x1
Standard equipment: 3 crocodile clips; carrying case; hand strap; mains battery charger; neckstrap; remote probe; screen protector preventing scratching (set); test leads; test probes; USB cable
Optional equipment: CA-C177A; CA-MN77
Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010; IEC 61326-1
Measuring instrument features: built-in fuse table; long operating time up to 30 hours; programmable alarm thresholds; test leads resistance compensation
Test voltage: 50V; 100V; 250V; 500V; 1kV
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: included
Insulation resistance measuring ranges: 0.01MΩ...2GΩ
Illumination: yes
Earthing resistance measuring range: 500mΩ...40Ω; 15kΩ; 40kΩ
Loop impedance measuring accuracy: ±(5% + 2 digit)
Earthing resistance measuring accuracy: ±(2% + 2 digit)
RCD test: AC, B, B+, EV, A and F-type RCDs; general purpose
Loop impedance measurement: 100...500mΩ; 4Ω; 40Ω; 400Ω
кількість в упаковці: 1 шт
товар відсутній
C.A 6131 C.A 6131 CHAUVIN ARNOUX HLHBIX5T.PDF CA-6116N_DS.PDF CA-6116N_M.PDF Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; VAC: 0÷800V; ±(1%+2digit); IP54
Dimensions: 223x126x70mm
Measuring instrument features: Pass/Fail function
Standard equipment: 3 crocodile clips; carrying case; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1
Measurement: AC voltage; continuity; insulation resistance; phase sequence; RCD tripping time; resistance
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x6
AC voltage measuring range: 0...800V
Resistance measuring range: 1...10Ω; 100kΩ
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Measurement memory: 2970
IP rating: IP54
Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1
Bargraph: yes
Loop impedance measuring range: 100mΩ...1Ω; 400Ω
Insulation resistance measuring ranges: 0...100MΩ; 1GΩ
AC voltage measuring accuracy: ±(1% + 2 digit)
Illumination: yes
Type of meter: appliance meter
Continuity test: <10Ω
RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
1+57367.09 грн
C.A 6133 C.A 6133 CHAUVIN ARNOUX HLHBIX5T.PDF Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; VAC: 2÷550V; 30÷1000Hz; Bluetooth
Dimensions: 223x126x70mm
Measuring instrument features: automatic generation of PDF file with recorded data; magnetized casing; Pass/Fail function
Standard equipment: 3 crocodile clips; battery charger/power supply; carrying case; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1; USB cable
Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance
Kind of display used: LCD
Interface: Bluetooth
Power supply: rechargeable battery Ni-MH AA x6
Software: dedicated mobile app
AC voltage measuring range: 2...550V
Resistance measuring range: 1...10Ω; 100kΩ
Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6
Measurement memory: 2970
IP rating: IP54
Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1
Bargraph: yes
Loop impedance measuring range: 100mΩ...1Ω; 400Ω
Frequency measuring range: 30...1000Hz
Earthing resistance measuring range: 500mΩ...100Ω; 1kΩ; 2kΩ
Insulation resistance measuring ranges: 0...100MΩ; 1GΩ
Frequency measuring accuracy: ±(0.1%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Illumination: yes
Type of meter: appliance meter
Continuity test: <10Ω
RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
1+67207.29 грн
C.A 6133 LAUNCH KIT
+2
C.A 6133 LAUNCH KIT CHAUVIN ARNOUX Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; VAC: 2÷550V; 30÷1000Hz; Bluetooth
Illumination: yes
IP rating: IP54
Dimensions: 223x126x70mm
Measurement memory: 2970
Standard equipment: 3 crocodile clips; battery charger/power supply; carrying case; continuity rod; kit for earth ground resistance measurement 15m; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1; USB cable
Measuring instrument features: automatic generation of PDF file with recorded data; magnetized casing; Pass/Fail function
Type of meter: appliance meter
Continuity test: <10Ω
RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose
Bargraph: yes
Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance
Resistance measuring range: 1...10Ω; 100kΩ
Loop impedance measuring range: 100mΩ...1Ω; 400Ω
AC voltage measuring range: 2...550V
Frequency measuring range: 30...1000Hz
Earthing resistance measuring range: 500mΩ...100Ω; 1kΩ; 2kΩ
Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6
Software: dedicated mobile app
Insulation resistance measuring ranges: 0...100MΩ; 1GΩ
Frequency measuring accuracy: ±(0.1%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Kind of display used: LCD
Power supply: rechargeable battery Ni-MH AA x6
Interface: Bluetooth
Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1
кількість в упаковці: 1 шт
на замовлення 2 шт:
термін постачання 7-14 дні (днів)
1+79645.96 грн
C.A 6165 CHAUVIN ARNOUX Category: Electrical Safety Testers
Description: Safety analyzer; Interface: Bluetooth,RS232; 435x292x155mm
Type of meter: safety analyzer
Supply voltage: 100...240V AC
IP rating: IP40
Dimensions: 435x292x155mm
Interface: Bluetooth; RS232
Kind of display used: LCD TFT
Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance
Software: dedicated mobile app
Insulation resistance measuring ranges: 0...20MΩ; 100MΩ
Measurement memory: 6000
Display resolution: 480x272
Standard equipment: carrying case; crocodile clips; EURO mains power cable; manual (CD); probe; RS232 cable; test leads; USB cable
Measuring instrument features: automatic generation of PDF file with recorded data; magnetized casing; Pass/Fail function
RCD test: 10mA, 30mA, 100mA, 300mA, 500mA, 1000mA ; general purpose
Test voltage: 50V; 100V; 250V; 500V; 1kV
кількість в упаковці: 1 шт
товар відсутній
C.A 6240 C.A 6240 CHAUVIN ARNOUX 6240dte_EN.pdf Category: Miliohmmeters
Description: Milli-ohm meter; LCD; R range: 400uΩ÷400Ω; ±(0.25%+2digit)
Type of meter: milli-ohm meter
Resistance measuring range: 400µΩ...400Ω
Resistance measuring accuracy: ±(0.25%+2 digit)
Measuring instrument features: automatic power-off
Conform to the norm: CAT III 50V; EN 61010
Power supply: rechargeable battery Ni-MH x1
Dimensions: 273x247x280mm
Standard equipment: Kelvin test leads; mains cable; USB cable; user's manual
Test current: 10mA @ 4Ω...39.99Ω; 10mA @ 40Ω...399.9Ω; 100mA @ 400mΩ...3999mΩ; 1A @ 4µΩ...39.99mΩ; 1A @ 40mΩ...399.9mΩ; 10A @ 5µΩ...3.999µΩ
Battery/ rechargeable battery: rechargeable battery Ni-MH x1
Software: included
Kind of display used: LCD
Interface: USB
кількість в упаковці: 1 шт
товар відсутній
C.A 6424 ca-6422-24-EN.pdf ca-6422-24-DE.pdf NF_CA6422_24_GB.pdf NF_CA6422_24_DE.pdf
C.A 6424
Виробник: CHAUVIN ARNOUX
Category: Earth Resistance Meter
Description: Meter: grounding resistance; LCD; 0.05÷50kΩ; IP65; Illumin: yes
Body dimensions: 223x126x70mm
Conform to the norm: CAT IV 600V; EN 61010; EN 61557
Illumination: yes
Standard equipment: carrying case; mains cable; power supply; user's manual
Type of meter: grounding resistance
Weight with battery: 1kg
Earthing resistance measuring accuracy: ±(2% + 1 digits)
Alias: P01127014
Earthing resistance measuring range: 0.05...50kΩ
Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6
Kind of display used: LCD
Power supply: rechargeable battery Ni-MH AA x6
IP rating: IP65
товар відсутній
C.A 6462
Виробник: CHAUVIN ARNOUX
Category: Earth Resistance Meter
Description: Meter: grounding resistance; LCD; (2000); 10mΩ÷20Ω,200Ω,2kΩ; IP53
IP rating: IP53
Body dimensions: 273x247x127mm
Conform to the norm: EN 61010-2-032; EN 61557
Illumination: yes
Standard equipment: user's manual
Type of meter: grounding resistance
Weight with battery: 3.35kg
Earthing resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ
Battery/ rechargeable battery: rechargeable battery Ni-MH x1
Display parameters: (2000)
Earthing resistance measuring accuracy: ±(2% + 1 digit)
Kind of display used: LCD
Power supply: rechargeable battery Ni-MH x1
товар відсутній
C.A 6503 CA-6503_M.PDF
C.A 6503
Виробник: CHAUVIN ARNOUX
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; analogue; 250V,500V,1kV; IP54
Type of meter: insulation resistance
Kind of display used: analogue
Insulation resistance measuring accuracy: ±2.5%
Test voltage: 250V; 500V; 1kV
Conform to the norm: CAT II 600V; CAT III 300V; EN 61010
Standard equipment: 3 crocodile clips; carrying case; test leads ( 3pcs.); test probe x1
Power supply: built-in magneto
IP rating: IP54
Weight without batteries: 1.06kg
Body dimensions: 120x120x130mm
Insulation resistance measuring ranges: 1...5000MΩ
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна без ПДВ
1+53227.53 грн
C.A 6524 CA-6524_DS.PDF CA-6524_M.PDF
C.A 6524
Виробник: CHAUVIN ARNOUX
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; (4000); VAC: 300mV÷400V,700V
Type of meter: insulation resistance
Kind of display used: LCD
Display parameters: (4000)
AC voltage measuring range: 300mV...400V; 700V
DC voltage measuring range: 300mV...400V; 700V
DC voltage measuring accuracy: ±(3% + 2 digit)
IP rating: IP54
Body dimensions: 211x108x60mm
Weight without batteries: 850g
Power supply: battery LR6 AA 1,5V x6
Conform to the norm: CAT IV 600V; EN 61243-3:2010; IEC 61010-1; IEC 61010-2-030; IEC 61326-1
Continuity test: <10Ω; <100Ω
Standard equipment: carrying case; crocodile clip; test leads; test probe x1
Test voltage: 50V; 100V; 250V; 500V; 1kV
Resistance measuring range: 4kΩ; 40kΩ; 400kΩ; 1MΩ
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Measurement memory: 300
Resistance measuring accuracy: ±(3%+2 digit)
Bargraph: yes
Insulation resistance measuring ranges: 10...999kΩ; 4MΩ; 40MΩ; 400MΩ; 4GΩ; 40GΩ; 200GΩ
Insulation resistance measuring accuracy: ±(3% + 2digit)
товар відсутній
C.A 6526 CA-6524_DS.PDF CA-6524_M.PDF
Виробник: CHAUVIN ARNOUX
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; (4000); VAC: 300mV÷400V,700V
Body dimensions: 211x108x60mm
Conform to the norm: CAT IV 600V; EN 61243-3:2010; IEC 61010-1; IEC 61010-2-030; IEC 61326-1
IP rating: IP54
Bargraph: yes
Test voltage: 50V; 100V; 250V; 500V; 1kV
Resistance measuring range: 4kΩ; 40kΩ; 400kΩ; 1MΩ
DC voltage measuring range: 300mV...400V; 700V
AC voltage measuring range: 300mV...400V; 700V
Capacitance measuring range: 0.1...400nF; 4µF; 10µF
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: included
Insulation resistance measuring ranges: 10...999kΩ; 4MΩ; 40MΩ; 400MΩ; 4GΩ; 40GΩ; 200GΩ
Display parameters: (4000)
DC voltage measuring accuracy: ±(3% + 2 digit)
Resistance measuring accuracy: ±(3%+2 digit)
Insulation resistance measuring accuracy: ±(3% + 2digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x6
Interface: Bluetooth
Measurement memory: 1300
Standard equipment: carrying case; crocodile clip; test leads; test probe x1
Type of meter: insulation resistance
Weight without batteries: 850g
Continuity test: <10Ω; <100Ω
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна без ПДВ
1+50922.78 грн
C.A 6528 CA-6528.pdf
C.A 6528
Виробник: CHAUVIN ARNOUX
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; (4000); R range: 1÷420kΩ; IP40
Type of meter: insulation resistance
Kind of display used: LCD
Display parameters: (4000)
Resistance measuring range: 1...420kΩ
Insulation resistance measuring accuracy: ±(1.5% + 10digit)
AC voltage measuring range: 0...700V
DC voltage measuring range: 0...700V
Continuity test: <40Ω
Test voltage: 250V; 500V; 1kV
Conform to the norm: IEC 61010-1; IEC 61010-2-030; IEC 61010-2-034; IEC 61326-1
Measuring instrument features: automatic power-off; HOLD function
Standard equipment: carrying case; crocodile clip; test leads; test probe x1
Power supply: battery LR6 AA 1,5V x6
IP rating: IP40
Weight without batteries: 760g
Body dimensions: 218x95x63mm
Insulation resistance measuring ranges: 50kΩ...11GΩ
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: included
Resistance measuring accuracy: ±(1.2%+3 digit)
товар відсутній
C.A 6547 CA-6547_DS.PDF CA-6547_M.PDF
C.A 6547
Виробник: CHAUVIN ARNOUX
Category: Insulation Resistance Meters
Description: Meter: megaohm meter; LCD; VAC: 1÷5100V; VDC: 1÷5100V; ±(5%+3digit)
IP rating: IP53
Body dimensions: 270x250x180mm
Interface: RS232
Conform to the norm: CAT III 1000V; EN 61010; IEC 61010-1; IEC 61557
Illumination: yes
Standard equipment: 1 lead with rear connection 0,35m length; carrying case; mains cable; test leads with crocodile clips
Measuring instrument features: settable MIN/MAX alarm thresholds
Type of meter: megaohm meter
Weight without batteries: 4.3kg
Test voltage: 50...5100V
DC voltage measuring range: 1...5100V
AC voltage measuring range: 1...5100V
Insulation resistance measuring ranges: 10kΩ...10TΩ
DC voltage measuring accuracy: ±(5% + 3 digit)
Insulation resistance measuring accuracy: ±(5% + 3digit)
Kind of display used: LCD
Power supply: rechargeable battery Ni-MH 1,2V 3,5Ah x8
Supply voltage: 85...265V AC
товар відсутній
C.A 6608 CA-6608-DTE.PDF ca-6608-M.PDF
Виробник: CHAUVIN ARNOUX
Category: Phase Sequence Indicators
Description: Tester: phase sequence; LCD; Freq: 15÷400Hz; IP40
Type of tester: phase sequence
Kind of display used: LCD
Phase-to-phase voltage range for phase sequence indication: 40...850V AC
Operating frequency: 15...400Hz
IP rating: IP40
Body dimensions: 130x69x32mm
Weight with battery: 130g
Power supply: from tested wiring system
Conform to the norm: CAT III 600V; EN 61010; IEC 61557-7
Measurement: motor's rotation direction; phase sequence
Standard equipment: 3 crocodile clips; case; test leads ( 3pcs.)
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна без ПДВ
1+12651.73 грн
C.A 6609 CA-6608-DTE.PDF CA-6609-M.PDF
Виробник: CHAUVIN ARNOUX
Category: Phase Sequence Indicators
Description: Tester: phase sequence; LED; Freq: 15÷400Hz; IP40
Operating frequency: 15...400Hz
Type of tester: phase sequence
Standard equipment: 3 crocodile clips; case; test leads ( 3pcs.)
Measuring instrument features: non-contact determination of rotation field direction; voltage indicator individual for each phase
Weight with battery: 170g
Phase-to-phase voltage range for phase sequence indication: 40...600V AC
IP rating: IP40
Power supply: battery 9V x1
Measurement: motor's rotation direction; phase sequence
Kind of display used: LED
Body dimensions: 130x69x32mm
Conform to the norm: CAT III 600V; EN 61010; IEC 61557-7
товар відсутній
C.A 6681 CA-6681_DS.PDF CA-6681_M.PDF
C.A 6681
Виробник: CHAUVIN ARNOUX
Category: Metals & cables detectors
Description: Wire localizer; LCD; 12÷300VAC,12÷300VDC; Output signal: 125kHz
Kind of display used: LCD
Standard equipment: a bayonet adapter B22; adapter for main socket; a earth spike; a screw adapter E27; case; crocodile clips; receiver; test leads; transmitter
Battery/ rechargeable battery: battery 6LR61 9V x7
Measuring instrument features: detection of a metallic water supply and heating pipe; detection of faults in an in floor heating system; detection of the constricted (plugged) part of nonmetallic pipe; identification of supply circuit on the same floor; identyfication of pairs
Detection: conductors at depth up to 2m (1-pole application); conductors at depth up to 0,5m (2-pole application); localisation of wire breaks; localises discontinuity in live conductors; localizes cable routes in ground; localizes given electric circuit protection; localizes routes of metal pipes for water and central heating systems; locating and tracing lines and outlets
Output signal: 125kHz
Detected voltage range: 12...300V AC; 12...300V DC
Bargraph: yes
Power supply: battery 6LR61 9V x7
Conform to the norm: CAT III 300V; EN 61010
Type of tester: wire localizer
Receiver dimensions: 241.5x78x38.5mm
Transmitter dimensions: 190x89x42.5mm
Additional functions: torch
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна без ПДВ
1+30293.85 грн
C.A 702 CA-703_DS.PDF ca-702-ins.PDF CA-703_M.PDF
Виробник: CHAUVIN ARNOUX
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (1999); VDC: 200mV,2V,20V,200V,600V
Type of meter: digital multimeter
Measuring instrument features: automatic power-off; autoranging; built-in measuring cables; contactless voltage detector; HOLD function; low battery indicator; pocket size
Kind of display used: LCD
DC voltage measuring range: 200mV; 2V; 20V; 200V; 600V
DC voltage measuring accuracy: ±(0.5% + 3 digit)
AC voltage measuring range: 2V; 20V; 200V; 600V
AC voltage measuring accuracy: ±(1% + 8 digit)
Resistance measuring range: 200Ω; 2kΩ; 20kΩ; 200kΩ; 2MΩ; 20MΩ
Resistance measuring accuracy: ±(0.08%+5 digit)
Diode test: 1mA @1.5V
Continuity test: acoustic indication; <60Ω
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: fixed test leads
Measurement: AC voltage; continuity; DC voltage; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions (W x H x D): 55x104x32.5mm
Additional functions: torch
Display parameters: (1999)
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна без ПДВ
1+3733.12 грн
C.A 7028
Виробник: CHAUVIN ARNOUX
Category: LAN and Telephone Networks Testers
Description: Tester: LAN wiring; LCD; 0÷40°C; 165x90x37mm; Illumin: yes
Type of tester: LAN wiring
Kind of display used: LCD
Detection: discontinuities and short circuits in conductors; place of cable failure; reversed connection; screening continuity; split pairs
Measurement: cable length; continuity
Power supply: battery LR6 AA 1,5V x4
Operating temperature: 0...40°C
Conform to the norm: EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-6; EN 61326-1; IEC 61010-1
Dimensions: 165x90x37mm
Measuring instrument features: automatic power-off; identyfication of pairs; low battery indicator; testing and identifying up to 9 links; voltage presence indicator; wiring schemes: TIA 568A/B, USOC & ISDN
Standard equipment: case; identifier; RJ45 connection cables
Related items: CA-P01101994; CA-P01101995
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Test: cables FTP; cables SSTP; cables STP; cables UTP
Illumination: yes
товар відсутній
C.A 703 CA-703_DS.PDF CA-703_M.PDF
C.A 703
Виробник: CHAUVIN ARNOUX
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (1999); VDC: 200mV,2V,20V,200V,600V
Type of meter: digital multimeter
Measuring instrument features: automatic power-off; autoranging; built-in measuring cables; contactless voltage detector; HOLD function; low battery indicator; pocket size
Kind of display used: LCD
DC voltage measuring range: 200mV; 2V; 20V; 200V; 600V
DC voltage measuring accuracy: ±(0.5% + 3 digit)
AC voltage measuring range: 2V; 20V; 200V; 600V
AC voltage measuring accuracy: ±(1% + 8 digit)
AC current measuring range: 0.2mA; 2mA; 20mA; 200mA
DC current measuring range: 0.2mA; 2mA; 20mA; 200mA
DC current measuring accuracy: ±(2% + 8 digit)
AC current measuring accuracy: ±(2.5% + 10 digit)
Resistance measuring range: 200Ω; 2kΩ; 20kΩ; 200kΩ; 2MΩ; 20MΩ
Resistance measuring accuracy: ±(0.08%+5 digit)
Diode test: 1mA @1.5V
Continuity test: acoustic indication; <60Ω
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: fixed test leads
Measurement: AC current; AC voltage; continuity; DC current; DC voltage; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Dimensions (W x H x D): 55x104x32.5mm
Additional functions: torch
Display parameters: (1999)
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна без ПДВ
1+4736.46 грн
C.A 732 CA-703_DS.PDF ca-732-ins.PDF
C.A 732
Виробник: CHAUVIN ARNOUX
Category: Indicators, Voltage & Continuity Testers
Description: Tester: non-contact voltage detector; 195÷265VAC; IP40
Power supply: battery LR03 AAA 1,5V x2
Additional functions: torch
IP rating: IP40
Conform to the norm: CAT III 1000V; EN 61010
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Detected voltage range: 195...265V AC
Type of tester: non-contact voltage detector
Measuring instrument features: contactless voltage detector; ergonomic case ensuring comfortable and precise operation
на замовлення 2 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна без ПДВ
1+2328.75 грн
2+ 2044.51 грн
C.A 742 CA-762_DS.PDF CA-742_M.PDF
Виробник: CHAUVIN ARNOUX
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; VAC: 12V,24V,50V,127V,230V,400V,690V
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: carrying strap; test lead; test probe x1
Body dimensions: 163x64x40mm
IP rating: IP65
Kind of display used: LEDs
Weight with battery: 210g
Conform to the norm: CAT IV 600V; EN 61010; IEC 61326-1
AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 690V
DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 750V
Resistance to: fall from 2m height
Measuring instrument features: AutoTest function; hazardous voltage indicator (>50V AC or 120V DC); low battery indicator; polarization indicator; single-pole voltage testing
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Type of tester: electrical
Continuity test: acoustic indication; optical indication; <100Ω
Bandwidth for AC voltage measurements: 16.66...800Hz
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна без ПДВ
1+5292.33 грн
C.A 742 IP2X CA-762_DS.PDF CA-742_M.PDF
Виробник: CHAUVIN ARNOUX
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; VAC: 12V,24V,50V,127V,230V,400V,690V
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: carrying strap; IP2X test probes; test lead
Body dimensions: 163x64x40mm
IP rating: IP65
Kind of display used: LEDs
Weight with battery: 210g
Conform to the norm: CAT IV 600V; EN 61010; IEC 61326-1; NF C 18-510
AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 690V
DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 750V
Resistance to: fall from 2m height
Measuring instrument features: AutoTest function; hazardous voltage indicator (>50V AC or 120V DC); low battery indicator; polarization indicator; single-pole voltage testing
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Type of tester: electrical
Continuity test: acoustic indication; optical indication; <100Ω
Bandwidth for AC voltage measurements: 16.66...800Hz
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна без ПДВ
1+6139.29 грн
C.A 745N CA-745N-DS.PDF
Виробник: CHAUVIN ARNOUX
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LCD; VAC: 0÷690V; 50/60Hz; VDC: 0÷690V; IP54
Type of tester: electrical
Kind of display used: LCD
AC voltage measuring range: 0...690V
Bandwidth for AC voltage measurements: 50/60Hz
DC voltage measuring range: 0...690V
Continuity test: acoustic indication; optical indication
IP rating: IP54
Conform to the norm: CAT III 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: low battery indicator; polarization indicator; single-pole voltage testing
Standard equipment: test probe x1
Body dimensions: 180x52x45mm
Weight with battery: 200g
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Bargraph: yes
на замовлення 3 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна без ПДВ
1+4528.98 грн
3+ 4148.69 грн
C.A 755 CA-757_DS.PDF
Виробник: CHAUVIN ARNOUX
Category: Portable digital multimeters
Description: Digital multimeter; LCD; VDC: 3V,30V,300V,1kV; Test: diodes; IP54
Type of meter: digital multimeter
Measurement: AC voltage; capacitance; continuity; DC voltage; resistance
Kind of display used: LCD
DC voltage measuring range: 3V; 30V; 300V; 1kV
DC voltage measuring accuracy: ±(2% + 3 digit)
AC voltage measuring range: 3V; 30V; 300V; 1kV
AC voltage measuring accuracy: ±(3% + 4 digit)
Resistance measuring range: 300Ω; 3kΩ; 30kΩ; 300kΩ; 3MΩ; 30MΩ
Capacitance measuring range: 3nF; 30nF; 300nF; 3µF; 30µF; 300µF; 3mF; 30mF
Capacitance measuring accuracy: ±(5%+ 5 digit)
Resistance measuring accuracy: ±(3%+3 digit)
Test: diodes
Continuity test: acoustic indication; <30Ω
IP rating: IP54
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: test probes
Conform to the norm: CAT III 600V; EN 61010
Resistance to: fall from 2m height
Dimensions (W x H x D): 180x52x45mm
Measuring instrument features: autoranging; contactless voltage detector; low battery indicator; replaceable measuring tips
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Illumination: yes
товар відсутній
C.A 757 CA-757_DS.PDF
Виробник: CHAUVIN ARNOUX
Category: Portable digital multimeters
Description: Digital multimeter; LCD; VDC: 3V,30V,300V,1kV; Test: diodes; IP54
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; continuity; DC voltage; resistance
Kind of display used: LCD
DC voltage measuring range: 3V; 30V; 300V; 1kV
DC voltage measuring accuracy: ±(2% + 3 digit)
AC voltage measuring range: 3V; 30V; 300V; 1kV
AC voltage measuring accuracy: ±(3% + 4 digit)
AC current measuring range: 500mA...30A; 300A
AC current measuring accuracy: ±(3% + 5 digit)
Resistance measuring range: 300Ω; 3kΩ; 30kΩ; 300kΩ; 3MΩ; 30MΩ
Capacitance measuring range: 3nF; 30nF; 300nF; 3µF; 30µF; 300µF; 3mF; 30mF
Capacitance measuring accuracy: ±(5%+ 5 digit)
Resistance measuring accuracy: ±(3%+3 digit)
Test: diodes
Continuity test: acoustic indication; <30Ω
IP rating: IP54
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: probe MiniFlex; test probes; Velcro strap
Conform to the norm: CAT III 600V; EN 61010
Resistance to: fall from 2m height
Dimensions (W x H x D): 180x52x45mm
Measuring instrument features: autoranging; contactless voltage detector; low battery indicator; replaceable measuring tips
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Illumination: yes
товар відсутній
C.A 762 CA-762_DS.PDF ca-762-m.PDF
Виробник: CHAUVIN ARNOUX
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 50÷690VAC; 16.66÷800Hz; IP65
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: carrying strap; test lead; test probe x1
Body dimensions: 163x64x40mm
IP rating: IP65
Kind of display used: LEDs
Weight with battery: 210g
Conform to the norm: CAT IV 600V; EN 61010; IEC 61326-1
AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 690V
DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 750V
Resistance to: fall from 2m height
Measuring instrument features: AutoTest function; hazardous voltage indicator (>50V AC or 120V DC); low battery indicator; polarization indicator; single-pole voltage testing
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Type of tester: electrical
Continuity test: acoustic indication; optical indication; 100Ω...2kΩ; 2kΩ...60kΩ; 60kΩ...300kΩ
Phase-to-phase voltage range for phase sequence indication: 50...690V AC
Bandwidth for AC voltage measurements: 16.66...800Hz
товар відсутній
C.A 762 IP2X CA-762_DS.PDF ca-762-m.PDF
Виробник: CHAUVIN ARNOUX
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 50÷690VAC; 16.66÷800Hz; IP65
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: carrying strap; IP2X test probes; test lead
Body dimensions: 163x64x40mm
IP rating: IP65
Kind of display used: LEDs
Weight with battery: 210g
Conform to the norm: CAT IV 600V; EN 61010; IEC 61326-1; NF C 18-510
AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 690V
DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 750V
Resistance to: fall from 2m height
Measuring instrument features: AutoTest function; hazardous voltage indicator (>50V AC or 120V DC); low battery indicator; polarization indicator; single-pole voltage testing
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Type of tester: electrical
Continuity test: acoustic indication; optical indication; 100Ω...2kΩ; 2kΩ...60kΩ; 60kΩ...300kΩ
Phase-to-phase voltage range for phase sequence indication: 50...690V AC
Bandwidth for AC voltage measurements: 16.66...800Hz
товар відсутній
C.A 771 CA-771-DS.PDF
Виробник: CHAUVIN ARNOUX
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 50÷1000VAC; 40÷65Hz; IP65; RCD test: 30mA
Power supply: battery LR6 AA 1,5V x2
Standard equipment: test probe x1; Velcro strap
Body dimensions: 228x60x39mm
IP rating: IP65
Kind of display used: LEDs
Weight with battery: 350g
Conform to the norm: CAT IV 1000V; EN 61010; EN 61243-3; IEC 61326-1
AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV
DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV; 1.4kV
Resistance to: fall from 2m height
Measuring instrument features: AutoTest function; phase sequence indication; polarization indicator; single-pole voltage testing
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Type of tester: electrical
Additional functions: torch
Continuity test: acoustic indication; optical indication
Phase-to-phase voltage range for phase sequence indication: 50...1000V AC
RCD test: 30mA
Bandwidth for AC voltage measurements: 40...65Hz
товар відсутній
C.A 771 IP2X CA-771-DS.PDF
Виробник: CHAUVIN ARNOUX
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 50÷1000VAC; 40÷65Hz; IP65; RCD test: 30mA
Power supply: battery LR6 AA 1,5V x2
Standard equipment: IP2X test probes; Velcro strap
Body dimensions: 228x60x39mm
IP rating: IP65
Kind of display used: LEDs
Weight with battery: 350g
Conform to the norm: CAT IV 1000V; EN 61010; EN 61243-3; IEC 61326-1; NF C 18-510
AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV
DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV; 1.4kV
Resistance to: fall from 2m height
Measuring instrument features: AutoTest function; phase sequence indication; polarization indicator; single-pole voltage testing
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Type of tester: electrical
Additional functions: torch
Continuity test: acoustic indication; optical indication
Phase-to-phase voltage range for phase sequence indication: 50...1000V AC
RCD test: 30mA
Bandwidth for AC voltage measurements: 40...65Hz
товар відсутній
C.A 773 CA-771-DS.PDF
Виробник: CHAUVIN ARNOUX
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 50÷1000VAC; 40÷65Hz; IP65
Power supply: battery LR6 AA 1,5V x2
Standard equipment: test probe x1; Velcro strap
Body dimensions: 228x60x39mm
IP rating: IP65
Kind of display used: LCD; LEDs
Weight with battery: 350g
Conform to the norm: CAT IV 1000V; EN 61010; IEC 61326-1
AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV
DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV; 1.4kV
Resistance to: fall from 2m height
Measuring instrument features: AutoTest function; low battery indicator; phase sequence indication; polarization indicator; single-pole voltage testing
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Illumination: yes
Type of tester: electrical
Additional functions: torch
Continuity test: acoustic indication; optical indication
Phase-to-phase voltage range for phase sequence indication: 50...1000V AC
RCD test: 30mA
Bandwidth for AC voltage measurements: 40...65Hz
товар відсутній
C.A 773 IP2X CA-771-DS.PDF
Виробник: CHAUVIN ARNOUX
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 50÷1000VAC; 40÷65Hz; IP65
Power supply: battery LR6 AA 1,5V x2
Standard equipment: IP2X test probes; Velcro strap
Body dimensions: 228x60x39mm
IP rating: IP65
Kind of display used: LCD; LEDs
Weight with battery: 350g
Conform to the norm: CAT IV 1000V; EN 61010; IEC 61326-1; NF C 18-510
AC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV
DC voltage measuring range: 12V; 24V; 50V; 127V; 230V; 400V; 600V; 1kV; 1.4kV
Resistance to: fall from 2m height
Measuring instrument features: AutoTest function; low battery indicator; phase sequence indication; polarization indicator; single-pole voltage testing
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Illumination: yes
Type of tester: electrical
Additional functions: 17 step speed regulation; torch
Continuity test: acoustic indication; optical indication
Phase-to-phase voltage range for phase sequence indication: 50...1000V AC
RCD test: 30mA
Bandwidth for AC voltage measurements: 40...65Hz
товар відсутній
C.A 8220 CA-8220_DS.PDF CA-8220_M.PDF
C.A 8220
Виробник: CHAUVIN ARNOUX
Category: Power Quality Analyzers
Description: Meter: power quality analyser; LCD; VAC: 6÷600V; True RMS; 40÷70Hz
Type of meter: power quality analyser
Measurement: AC current (with current clamps); active power; AC voltage; apparent power; DC current (with current clamps); Displacement Power Factor (DPF); frequency; harmonics; inrush current; power factor; reactive power; resistance; rpm velocity; temperature (option)
Kind of display used: LCD
AC voltage measuring range: 6...600V
True effective value measurement: True RMS
Frequency measuring range: 40...70Hz
Continuity test: acoustic indication
Pollution degree: 2
IP rating: IP54
Dimensions: 211x108x60mm
Weight with battery: 880g
Power supply: battery LR6 AA 1,5V x6
Standard equipment: 2 crocodile clips; optical cable with USB; test leads ( 2pcs.); test probes
Optional equipment: CA-1711 techometr probe
Conform to the norm: CAT III 600V; EN 61010
Measuring instrument features: automatic power-off; automatic recognition various current detectors; datalogging; indicates phase sequence
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: Power Analyser Transfer
Illumination: yes
на замовлення 1 шт:
термін постачання 21-30 дні (днів)
Кількість Ціна без ПДВ
1+60772.73 грн
C.A 8336 CA-8336_DS.PDF
C.A 8336
Виробник: CHAUVIN ARNOUX
Category: Power Quality Analyzers
Description: Meter: power quality analyser; colour,LCD TFT; Interface: USB
IP rating: IP53
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; IEC 61000-4-30
Kind of network: three-phase
Interface: USB
Display resolution: 320x240
Dimensions: 240x180x55mm
Standard equipment: 12-colour set to mark leads and inputs; aligator clip x5; carrying case; mains cable; manual (CD); screen protector preventing scratching (set); test leads ( 5pcs.); USB cable
Measuring instrument features: automatic recognition various current detectors; more than 450 recordable values with the required parameters and graphic displays; operation of several modes in parallel; possibility of viewing the data during a campaign; up to 40 alarms can be set simultaneously
Type of meter: power quality analyser
Producer guarantee (months): 36
Measurement: AC current (with current clamps); active power; AC voltage; apparent power; DC current (option); DC voltage; distorting power; energy; harmonics; inrush current; K factor for transformers; reactive power; short or long-term flicker
Software: Power Analyser Transfer
Kind of display used: colour; LCD TFT
Number of inputs: 9
Power supply: rechargeable battery Ni-MH x1
Supply voltage: 100...240V AC
товар відсутній
C.A 850
Виробник: CHAUVIN ARNOUX
Category: Manometers and Pressure Meters
Description: Manometer; -100÷100psi; LCD; Meas.accur: ±0,3%; 0÷50°C
Type of meter: manometer
Pressure measuring range: -100...100psi
Kind of display used: LCD
Measurement accuracy: ±0,3%
Dimensions: 72x182x30mm
Power supply: battery 6LR61 9V x1
Measuring instrument features: AUTO HOLD; automatic power-off; differential pressure measurements; logging of MAX, MIN
Standard equipment: 2 connection tubes; soft case; user's manual
Measurement: pressure
Measuring unit: bar; cm H2O; ft H2O; in Hg; in H2O; kg/cm2; kPa; mm Hg; ozin2
Operating temperature: 0...50°C
Measuring resolution: 0,01 psi
Battery/ rechargeable battery: battery 6LR61 9V x1
Illumination: yes
товар відсутній
C.A 1110 CA-1110_DS.PDF
C.A 1110
Виробник: CHAUVIN ARNOUX
Category: Luxmeters
Description: Light meter; 0,1÷200000lx; 3%; Bluetooth,USB; -10÷60°C; IP50
Type of meter: light meter
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MAP mode; MIN/MAX/MEDIUM function
Operating temperature: -10...60°C
Conform to the norm: IEC 61010-1; IEC 61326-1
Power supply: battery LR6 AA 1,5V x3
Dimensions: 150x72x32mm
Standard equipment: case; USB cable
Kind of measured light: fluorescent; LED; standard
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Kind of display used: LCD
IP rating: IP50
Interface: Bluetooth; USB
Measurement accuracy: 3%
Resistance to: fall from 1m height
Illumination: yes
Measurement memory: 1000000
Measuring range: 0,1...200000lx
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+32930.1 грн
3+ 31597.26 грн
C.A 1246 CA-1246_DS.PDF
Виробник: CHAUVIN ARNOUX
Category: Thermohygrometers
Description: Thermo-hygrometer; LCD; -10÷60°C; 3÷98%RH; ±(0.5%+1digit); 0.1°C
Type of meter: thermo-hygrometer
Measurement: dew point; humidity; temperature
Measuring instrument features: automatic power-off; data logger function; HOLD function; MIN/MAX function; programmable alarm thresholds
Conform to the norm: IEC 61010-1; IEC 61326-1
Power supply: battery LR6 AA 1,5V x3
Dimensions: 187x72x32mm
Standard equipment: case; USB cable
Temperature measurement resolution: 0.1°C
Temperature measuring range: -10...60°C
Humidity measuring range: 3...98% RH
Dew-point measurement: -10...60°C
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Temperature measurement accuracy: ±(0.5% + 1 digit)
Kind of display used: LCD
IP rating: IP54
Interface: Bluetooth; USB
Illumination: yes
Measurement memory: 1000000
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+25603.84 грн
C.A 1510
Виробник: CHAUVIN ARNOUX
Category: Gas Meters and Loggers
Description: Meter: CO2, temperature and humidity; Range: 0÷5000ppm,5÷95%
Kind of display used: LCD
Body dimensions: 125x65.5x32mm
IP rating: IP40
Temperature measuring range: -10...60°C
Measurement accuracy: ± (50 ppm + 3% of the value measured)
Standard equipment: USB adapter; USB/USB Micro cable; user's manual
Measuring instrument features: alarm activated on limit values exceeding
Type of meter: CO2, temperature and humidity
Humidity measuring accuracy: ±2% RH
Measuring resolution: 0,1%; 0,1°C; 1ppm
Event memory: 1M
Measurement: CO2; humidity; temperature
Software: compatible Android; compatible Windows 7; compatible Windows 8.1; compatible Windows 10; Data Logger Transfer
Temperature measurement accuracy: ±0.5°C
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth; USB
Illumination: yes
Measuring range: 0...5000ppm; 5...95%
кількість в упаковці: 1 шт
товар відсутній
C.A 1631
Виробник: CHAUVIN ARNOUX
Category: Calibrators
Description: Meter: calibrator; voltage,current; VDC: 0÷100mV,10V; I DC: 0÷24mA
Type of meter: calibrator
Measurement: DC current; DC voltage
Measuring instrument features: 24V loop supply voltage
Power supply: battery GR03 AAA 1,5V x6
Dimensions: 205x97x45mm
Standard equipment: case; insulated crocodile clips; set of test leads with probes
Kind of calibrator: current; voltage
DC current measuring range: 0...24mA
DC voltage measuring range: 0...100mV; 10V
Battery/ rechargeable battery: battery GR03 AAA 1,5V x6
Current source: 0...24mA
Voltage source: 0...100mV; 0...20V
DC voltage measuring accuracy: ±(0.02% + 3 digit)
DC current measuring accuracy: ±(0.015% + 3 digit)
Kind of display used: LCD
Illumination: yes
кількість в упаковці: 1 шт
товар відсутній
C.A 1821 CA-1820-DS.PDF CA-1820-INS.PDF
Виробник: CHAUVIN ARNOUX
Category: Temperature and Humidity Loggers
Description: Data logger; temperature; ±(0.2%+0.6°C); Temp: -250÷1767°C; IP54
Type of meter: data logger
Measurement: temperature
Temperature measurement accuracy: ±(0.2% + 0.6°C)
Power supply: battery LR6 AA 1,5V x3
Standard equipment: case; USB cable
Temperature measuring range: -250...1767°C
Interface: Bluetooth; USB
IP rating: IP54
Kind of display used: LCD
Dimensions: 150x72x32mm
Kind of temperature sensor: thermocouple E; thermocouple J; thermocouple K; thermocouple N; thermocouple R; thermocouple S; thermocouple T
Operating temperature: -10...60°C
Number of channels: 1
Temperature measuring range (with K-type thermocouple): -200...1372°C
Temperature measuring range (with J-type thermocouple): -210...1200°C
Temperature measuring range (with T-type thermocouple): -250...400°C
Temperature measuring range with N-type thermocouple: -200...1300°C
Temperature measuring range (with R-type thermocouple): 0...1767°C
Temperature measuring range (with S-type thermocouple): 0...1767°C
Temperature measuring range (with E-type thermocouple): -150...950°C
Producer guarantee (months): 24
Measuring instrument features: automatic power-off; HOLD function; long operating time up to 3 years (at 15-minute measurement interval); MIN/MAX function; programmable alarm thresholds
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Measurement memory: 100000
Software: dedicated mobile app
Supported formats: EXCEL
Illumination: yes
кількість в упаковці: 1 шт
товар відсутній
C.A 1822 CA-1820-DS.PDF CA-1820-INS.PDF
Виробник: CHAUVIN ARNOUX
Category: Temperature and Humidity Loggers
Description: Data logger; differential temperature,temperature; IP54; Ch: 2
Type of meter: data logger
Measurement: differential temperature; temperature
Temperature measurement accuracy: ±(0.2% + 0.6°C)
Power supply: battery LR6 AA 1,5V x3
Standard equipment: case; USB cable
Temperature measuring range: -250...1767°C
Interface: Bluetooth; USB
IP rating: IP54
Kind of display used: LCD
Dimensions: 150x72x32mm
Kind of temperature sensor: thermocouple E; thermocouple J; thermocouple K; thermocouple N; thermocouple R; thermocouple S; thermocouple T
Operating temperature: -10...60°C
Number of channels: 2
Temperature measuring range (with K-type thermocouple): -200...1372°C
Temperature measuring range (with J-type thermocouple): -210...1200°C
Temperature measuring range (with T-type thermocouple): -250...400°C
Temperature measuring range with N-type thermocouple: -200...1300°C
Temperature measuring range (with R-type thermocouple): 0...1767°C
Temperature measuring range (with S-type thermocouple): 0...1767°C
Temperature measuring range (with E-type thermocouple): -150...950°C
Producer guarantee (months): 24
Measuring instrument features: automatic power-off; HOLD function; long operating time up to 3 years (at 15-minute measurement interval); MIN/MAX function; programmable alarm thresholds
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Measurement memory: 100000
Software: dedicated mobile app
Supported formats: EXCEL
Illumination: yes
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+22858.58 грн
3+ 21360.47 грн
C.A 1823 CA-1820-DS.PDF CA-1820-INS.PDF
Виробник: CHAUVIN ARNOUX
Category: Temperature and Humidity Loggers
Description: Data logger; temperature; ±(0.4%+0.3°C); Temp: -100÷400°C; IP54
Type of meter: data logger
Measurement: temperature
Temperature measurement accuracy: ±(0.4% + 0.3°C)
Power supply: battery LR6 AA 1,5V x3
Standard equipment: case; USB cable
Temperature measuring range: -100...400°C
Interface: Bluetooth; USB
IP rating: IP54
Kind of display used: LCD
Dimensions: 150x72x32mm
Kind of temperature sensor: Pt100; Pt1000
Operating temperature: -10...60°C
Number of channels: 1
Producer guarantee (months): 24
Measuring instrument features: automatic power-off; HOLD function; long operating time up to 3 years (at 15-minute measurement interval); MIN/MAX function; programmable alarm thresholds
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Measurement memory: 100000
Software: dedicated mobile app
Supported formats: EXCEL
Illumination: yes
кількість в упаковці: 1 шт
товар відсутній
C.A 1866
Виробник: CHAUVIN ARNOUX
Category: Pirometers
Description: Infrared thermometer; LCD; -50÷1000°C; Accur: ±2°C; ±1.5%; ε: 0,1÷1
Type of meter: infrared thermometer
Kind of display used: LCD
Non-contact temperature measuring range: -50...1000°C
Temperature measurement accuracy: ±1.5%; ±2°C
Non-contact temperature measuring resolution: 0.1°C
Optical resolution: 50:1
Emissivity value: 0,1...1
Measurement: non-contact temeprature (IR)
Measuring unit: °C; °F
Dimensions: 230x100x56mm
Power supply: battery 9V x1
Measuring instrument features: adjustable emissivity; automatic power-off; HOLD function; laser sight; low battery indicator; MIN/MAX/MEDIUM function
Battery/ rechargeable battery: battery 9V x1
Illumination: yes
кількість в упаковці: 1 шт
товар відсутній
C.A 1950 P01651901 CA-1950_DS.PDF CA-1950_M.PDF
Виробник: CHAUVIN ARNOUX
Category: Infrared Cameras - Others
Description: Infrared camera; LCD 2,8"; 80x80; 9Hz; -20÷250°C; Focus: automatic
Type of meter: infrared camera
Kind of display used: LCD 2,8"
Camera resolution: 80x80
Refresh rate: 9Hz
Temperature measuring range: -20...250°C
Temperature measurement accuracy: ±2%; ±2°C
Focusing: automatic
IP rating: IP54
Body dimensions: 225x125x83mm
Weight with battery: 700g
Power supply: rechargeable battery Ni-MH x4
Measuring instrument features: Bluetooth communication with clamp meters and multimeters; socket for mounting on a stand; temperature markers (min, max); thermal or real image; voice annotation
Standard equipment: Bluetooth earphones; hard case; mains battery charger; microSDHC memory card; USB cable; user's manual
Thermal sensitivity (NETD): ≤0.08 @ 30°C
Three-dimensional resolution: 4.4mrad
Emissivity value: 0,05...1
Interface: Bluetooth; USB
Resistance to: fall from 2m height
Related items: CA-F407; CA-F607
Battery/ rechargeable battery: rechargeable battery Ni-MH x4
Software: included
Field of observation: 20° horizontal x 20° vertical
кількість в упаковці: 1 шт
товар відсутній
C.A 1954 P01651904 HLHBEMGI.PDF CA-1954-INS.PDF
Виробник: CHAUVIN ARNOUX
Category: Infrared Cameras - Others
Description: Infrared camera; LCD 2,8"; 160x120; 9Hz; -20÷250°C; IP54; 4.1mrad
Type of meter: infrared camera
Kind of display used: LCD 2,8"
Camera resolution: 160x120
Refresh rate: 9Hz
Temperature measuring range: -20...250°C
Temperature measurement accuracy: ±2%; ±2°C
Focusing: focus free
IP rating: IP54
Body dimensions: 225x125x83mm
Weight with battery: 700g
Power supply: rechargeable battery Ni-MH x4
Measuring instrument features: Bluetooth communication with clamp meters and multimeters; socket for mounting on a stand; temperature markers (min, max); thermal or real image; voice annotation
Standard equipment: Bluetooth earphones; hard case; mains battery charger; microSDHC memory card; USB cable; user's manual
Thermal sensitivity (NETD): ≤0.08 @ 30°C
Three-dimensional resolution: 4.1mrad
Emissivity value: 0,05...1
Interface: Bluetooth; USB
Resistance to: fall from 2m height
Related items: CA-F407; CA-F607
Battery/ rechargeable battery: rechargeable battery Ni-MH x4
Software: included
Field of observation: 38° horizontal x 28° vertical
кількість в упаковці: 1 шт
товар відсутній
C.A 5001 CA-5000-DS.PDF CA-5001-INS.PDF
Виробник: CHAUVIN ARNOUX
Category: Analog Multimeters
Description: Analogue multimeter; Features: blown fuse indicator; IP40
Type of meter: analogue multimeter
Measuring instrument features: blown fuse indicator
DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV
DC voltage measuring accuracy: ±1.5%
AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV
AC voltage measuring accuracy: ±2.5%
AC current measuring range: 5mA; 50mA; 0.5A; 5A
DC current measuring range: 50µA; 5mA; 50mA; 500mA; 5A
DC current measuring accuracy: ±2.5%
AC current measuring accuracy: ±2.5%
Resistance measuring range: 5...1MΩ
Resistance measuring accuracy: ±10%
Continuity test: acoustic indication; <50Ω
Power supply: battery LR6 AA 1,5V x1
Standard equipment: test leads; test probes
Measurement: AC current; AC voltage; DC current; DC voltage; resistance
Conform to the norm: CAT III 600V; EN 61010
Body dimensions: 56x105x160mm
Battery/ rechargeable battery: battery LR6 AA 1,5V x1
IP rating: IP40
Input impedance for AC voltage: 6.32kΩ/V
Input impedance for DC voltage measurement: 20kΩ/V
Producer guarantee (months): 36
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+22655.12 грн
C.A 5003 CA-5000-DS.PDF CA-5003-INS.PDF
Виробник: CHAUVIN ARNOUX
Category: Analog Multimeters
Description: Analogue multimeter; VDC: 100mV,1V,3V,10V,30V,100V,300V,1kV
Type of meter: analogue multimeter
Measuring instrument features: automatic calibration; blown fuse indicator
DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV
DC voltage measuring accuracy: ±1.5%
AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV
AC voltage measuring accuracy: ±2.5%
AC current measuring range: 1.5mA; 15mA; 150mA; 1.5A; 15A
DC current measuring range: 50µA; 150µA; 1.5mA; 15mA; 150mA; 1.5A; 15A
DC current measuring accuracy: ±2.5%
AC current measuring accuracy: ±2.5%
Resistance measuring range: 5...1MΩ
Resistance measuring accuracy: ±10%
Continuity test: acoustic indication; <50Ω
Power supply: battery 6F22 9V x1
Standard equipment: test leads; test probes
Measurement: AC current; AC voltage; DC current; DC voltage; resistance
Conform to the norm: CAT III 600V; EN 61010
Body dimensions: 56x105x160mm
Battery/ rechargeable battery: battery 6F22 9V x1
IP rating: IP53
Input impedance for AC voltage: 6.32kΩ/V
Input impedance for DC voltage measurement: 20kΩ/V
Producer guarantee (months): 36
кількість в упаковці: 1 шт
на замовлення 2 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+30251.73 грн
C.A 5005 + MN89 CA-5000-DS.PDF CA-5005-MN89.PDF
Виробник: CHAUVIN ARNOUX
Category: Analog Multimeters
Description: Analogue multimeter; VDC: 100mV,1V,3V,10V,30V,100V,300V,1kV
Type of meter: analogue multimeter
Measuring instrument features: automatic calibration; blown fuse indicator
DC voltage measuring range: 100mV; 1V; 3V; 10V; 30V; 100V; 300V; 1kV
DC voltage measuring accuracy: ±1.5%
AC voltage measuring range: 10V; 30V; 100V; 300V; 1kV
AC voltage measuring accuracy: ±2.5%
AC current measuring range: 3A; 10A; 30A; 100A; 240A
DC current measuring range: 50µA; 1mA; 10mA; 100mA; 1A; 10A
DC current measuring accuracy: ±2.5%
AC current measuring accuracy: ±2.5%
Resistance measuring range: 5...1MΩ
Resistance measuring accuracy: ±10%
Continuity test: acoustic indication; <50Ω
Power supply: battery 6F22 9V x1
Standard equipment: CA-MN89 - current clamp; holster; test leads
Measurement: AC current (with current clamps); AC voltage; DC current; DC voltage; resistance
Conform to the norm: CAT III 600V; EN 61010
Body dimensions: 56x105x160mm
IP rating: IP53
Input impedance for AC voltage: 6.32kΩ/V
Input impedance for DC voltage measurement: 20kΩ/V
Producer guarantee (months): 36
кількість в упаковці: 1 шт
товар відсутній
C.A 5011 ca-5011-dte.PDF ca-5011-ins.PDF
Виробник: CHAUVIN ARNOUX
Category: Analog Multimeters
Description: Analogue multimeter; analogue,LCD; (4000); Test: diodes; IP53
Type of meter: analogue multimeter
Measuring instrument features: HOLD function; impact resistant holster; MAX function
Kind of display used: analogue; LCD
Display parameters: (4000)
DC voltage measuring range: 400mV; 4V; 40V; 400V; 1kV
DC voltage measuring accuracy: ±(1% + 2 digits)
AC voltage measuring range: 400mV; 4V; 40V; 400V; 1kV
AC voltage measuring accuracy: ±(1,5% + 5 digits)
DC current measuring range: 0.4mA; 4mA; 40mA; 400mA; 1A; 10A
AC current measuring range: 0.4mA; 4mA; 40mA; 400mA; 1A; 10A
DC current measuring accuracy: ±(1,5% + 2 digits)
AC current measuring accuracy: ±(2% + 5 digits)
Resistance measuring accuracy: ±(1% + 2 digits)
Test: diodes
Continuity test: acoustic indication; <400Ω
Power supply: battery 6F22 9V x1
Standard equipment: test leads; test probes
Measurement: AC current; AC voltage; DC current; DC voltage; resistance
Conform to the norm: CAT III 600V; EN 61010
Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 40MΩ
Body dimensions: 56x105x160mm
IP rating: IP53
Producer guarantee (months): 36
Frequency measuring range: 4kHz; 40kHz; 100kHz
True effective value measurement: True RMS
Battery/ rechargeable battery: battery 6F22 9V x1
Alias: P01196311E
Illumination: yes
кількість в упаковці: 1 шт
товар відсутній
C.A 5231 CA-5231-M.PDF
Виробник: CHAUVIN ARNOUX
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 3x/s; True RMS
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
IP rating: IP54
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Resistance to: fall from 1m height
Illumination: yes
Standard equipment: test leads
Measuring instrument features: auto and manual ranging; automatic power-off; contactless voltage detector; HOLD function; low battery indicator; low input impedance function (LoZ)
Type of meter: digital multimeter
Test: diodes
Continuity test: acoustic indication
Sampling: 3x/s
True effective value measurement: True RMS
Bargraph: 61 segm.
Producer guarantee (months): 12
Measurement: AC current (with current clamps); AC voltage; continuity; DC current (with current clamps); DC voltage; resistance
Dimensions (W x H x D): 75x155x75mm
Bandwidth for AC voltage measurements: 45...60Hz; 60Hz...1kHz
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ
DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: (6000)
DC voltage measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(0.3%+4 digit)
кількість в упаковці: 1 шт
на замовлення 2 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+13414.14 грн
3+ 12765.75 грн
C.A 5231 KIT
Виробник: CHAUVIN ARNOUX
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 3x/s; True RMS
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
IP rating: IP54
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Resistance to: fall from 1m height
Illumination: yes
Standard equipment: CA-MINI-03 - current clamp; test leads
Measuring instrument features: auto and manual ranging; automatic power-off; contactless voltage detector; HOLD function; low battery indicator; low input impedance function (LoZ)
Type of meter: digital multimeter
Test: diodes
Continuity test: acoustic indication
Sampling: 3x/s
True effective value measurement: True RMS
Bargraph: 61 segm.
Producer guarantee (months): 12
Measurement: AC current (with current clamps); AC voltage; continuity; DC current (with current clamps); DC voltage; resistance
Dimensions (W x H x D): 75x155x75mm
Bandwidth for AC voltage measurements: 45...60Hz; 60Hz...1kHz
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ
DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: (6000)
DC voltage measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(0.3%+4 digit)
кількість в упаковці: 1 шт
товар відсутній
C.A 5233 CA-5233-M.PDF
Виробник: CHAUVIN ARNOUX
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 3x/s; True RMS
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Kind of display used: LCD
Display parameters: (6000)
Bargraph: 61 segm.
Sampling: 3x/s
DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(2% + 3 digit)
Bandwidth for AC voltage measurements: 45...60Hz; 60Hz...1kHz
DC current measuring range: 6A; 10A; 15A < 60s
DC current measuring accuracy: ±(1.5% + 3 digit)
AC current measuring range: 6A; 10A; (15A <60s)
AC current measuring accuracy: ±(2% + 3 digit)
Bandwidth for AC current measurements: 40Hz...1kHz
True effective value measurement: True RMS
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ
Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 1mF
Capacitance measuring accuracy: ±(3.5%+ 4 digit)
Frequency measuring range: 10...3000Hz
Frequency measuring accuracy: ±0.5%
Temperature measurement accuracy: ±(2% + 5°C)
Temperature measuring range (with K-type thermocouple): -20...760°C
Resistance measuring accuracy: ±(0.3%+4 digit)
Duty cycle factor: 0.1...99.9%
Test: diodes
Continuity test: acoustic indication
IP rating: IP54
Power supply: battery 6LR61 9V x1
Standard equipment: banana plug - K plug adapter; drop-like K-type temperature probe; test leads
Conform to the norm: CAT III 600V; CAT IV 600V; EN 61010
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Resistance to: fall from 1m height
Dimensions (W x H x D): 75x155x75mm
Producer guarantee (months): 12
Measuring instrument features: auto and manual ranging; automatic power-off; contactless voltage detector; HOLD function; low battery indicator; low input impedance function (LoZ); MIN/MAX/REL function
Battery/ rechargeable battery: battery 6LR61 9V x1
Illumination: yes
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+16462.27 грн
3+ 15625.28 грн
C.A 5273 CA-5273_DS.PDF CA-5273_M.PDF
C.A 5273
Виробник: CHAUVIN ARNOUX
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 5x/s; True RMS
Type of meter: digital multimeter
Measuring instrument features: auto and manual ranging; automatic calibration; automatic power-off; HOLD function; low input impedance function (LoZ); low-pass filter; MIN/MAX function
Kind of display used: LCD
Bargraph: 61 segm.
Sampling: 5x/s
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1.2% + 3 digit)
Bandwidth for AC voltage measurements: 40...400Hz; 400Hz...3kHz
AC current measuring range: 6A; 10A
DC current measuring range: 6A; 10A; 20A < 30s
DC current measuring accuracy: ±(0.8% + 2 digit)
AC current measuring accuracy: ±(1% + 3 digit)
Bandwidth for AC current measurements: 40Hz...1kHz
True effective value measurement: True RMS
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ
Resistance measuring accuracy: ±(1%+2 digit)
Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF
Capacitance measuring accuracy: ±(1%+ 5 digit)
Frequency measuring range: 100mHz...600Hz; 6kHz; 60kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
Temperature measurement accuracy: ±(0.5% + 2°C)
Test: diodes
Continuity test: acoustic indication
Power supply: battery 6F22 9V x1
Standard equipment: drop-like K-type temperature probe; test leads; test probes
Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Temperature measuring range (with K-type thermocouple): -59.6...1200°C
Dimensions (W x H x D): 90x190x45mm
Display parameters: (6000)
Illumination: yes
Battery/ rechargeable battery: battery 6F22 9V x1
IP rating: IP54
Resistance to: fall from 1m height
Producer guarantee (months): 36
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+23766.24 грн
C.A 5275 CA-5273_DS.PDF CA-5275-M.PDF
Виробник: CHAUVIN ARNOUX
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 5x/s; True RMS
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
IP rating: IP54
Power supply: battery 6F22 9V x1
Kind of display used: LCD
Resistance to: fall from 1m height
Illumination: yes
Standard equipment: case; MultiFIX mounting system; test leads; test probes
Measuring instrument features: auto and manual ranging; automatic calibration; automatic power-off; HOLD function; ionization current measurement; low input impedance function (LoZ); low-pass filter; MIN/MAX function; selection of AC or AC+DC measurement
Type of meter: digital multimeter
Test: diodes
Continuity test: acoustic indication
Sampling: 5x/s
True effective value measurement: True RMS
Bargraph: 61 segm.
Producer guarantee (months): 36
Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 90x190x45mm
Bandwidth for AC voltage measurements: 40...400Hz; 400Hz...10kHz
AC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; (20A <30s)
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ
Bandwidth for AC current measurements: 40Hz...1kHz
DC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 100mHz...600Hz; 6kHz; 60kHz
Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF
Battery/ rechargeable battery: battery 6F22 9V x1
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
AC current measuring accuracy: ±(1% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.8% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(1%+2 digit)
кількість в упаковці: 1 шт
на замовлення 3 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+27889.23 грн
3+ 26297.45 грн
C.A 5277 CA-5273_DS.PDF CA-5277-M.PDF
Виробник: CHAUVIN ARNOUX
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 61segm; 5x/s; True RMS
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
Temperature measuring range (with K-type thermocouple): -59.6...1200°C
Temperature measurement accuracy: ±(0.5% + 2°C)
Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance; temperature
Sampling: 5x/s
Resistance to: fall from 1m height
Power supply: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
IP rating: IP54
Producer guarantee (months): 36
Measuring instrument features: auto and manual ranging; automatic calibration; automatic power-off; HOLD function; ionization current measurement; low input impedance function (LoZ); low-pass filter; MIN/MAX/DIF/AVG function; MIN/MAX function; PEAK function; selection of AC or AC+DC measurement
Standard equipment: case; drop-like K-type temperature probe; MultiFIX mounting system; test leads; test probes
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Battery/ rechargeable battery: battery 6F22 9V x1
Illumination: yes
Capacitance measuring accuracy: ±(1%+ 5 digit)
Test: diodes
Continuity test: acoustic indication
True effective value measurement: True RMS
Bargraph: 61 segm.
Dimensions (W x H x D): 90x190x45mm
Bandwidth for AC voltage measurements: 40...400Hz; 400Hz...10kHz
AC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; (20A <30s)
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ
Bandwidth for AC current measurements: 40Hz...1kHz
DC current measuring range: 6mA; 60mA; 600mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 60mV; 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 100mHz...600Hz; 6kHz; 60kHz
Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF
Frequency measuring accuracy: ±(0.1%+2 digit)
AC current measuring accuracy: ±(1% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.8% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(1%+2 digit)
кількість в упаковці: 1 шт
на замовлення 2 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+29961.88 грн
3+ 28621.27 грн
C.A 5292 CA-5293.PDF
C.A 5292
Виробник: CHAUVIN ARNOUX
Category: Portable digital multimeters
Description: Digital multimeter; USB; colour,LCD; (100000); 5x/s; True RMS
Type of meter: digital multimeter
Kind of display used: colour; LCD
Display parameters: (100000)
Temperature measuring range: -200...800°C
Temperature measuring range (with K-type thermocouple): -40...1200°C
Temperature measurement accuracy: ±0.1%
Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Sampling: 5x/s
Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K
Interface: USB
Power supply: rechargeable battery Ni-MH AA 1,2V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
IP rating: IP67
Producer guarantee (months): 36
Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement
Standard equipment: case; mains battery charger; test leads; test probes; USB cable
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4
Software: included
Illumination: yes
Test: diodes
Continuity test: acoustic indication
Event memory: 10000
True effective value measurement: True RMS
Dimensions (W x H x D): 90x169x47.1mm
AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s)
Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s
DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV
AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV
Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz
Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
DC voltage measuring accuracy: ±(0.03% + 8 digit)
DC current measuring accuracy: ±(0.08% + 8 digit)
Resistance measuring accuracy: ±(0.07%+8 digit)
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+57729.41 грн
3+ 54917.83 грн
C.A 5292-BT CA-5293.PDF
C.A 5292-BT
Виробник: CHAUVIN ARNOUX
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth,USB; colour,LCD; (100000); 5x/s
Type of meter: digital multimeter
Kind of display used: colour; LCD
Display parameters: (100000)
Temperature measuring range: -200...800°C
Temperature measuring range (with K-type thermocouple): -40...1200°C
Temperature measurement accuracy: ±0.1%
Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Sampling: 5x/s
Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K
Interface: Bluetooth; USB
Power supply: rechargeable battery Ni-MH AA 1,2V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
IP rating: IP67
Producer guarantee (months): 36
Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement
Standard equipment: case; mains battery charger; test leads; test probes; USB cable
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4
Software: included
Illumination: yes
Test: diodes
Continuity test: acoustic indication
Event memory: 30000
True effective value measurement: True RMS
Dimensions (W x H x D): 90x169x47.1mm
AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s)
Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s
DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV
AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV
Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz
Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
DC voltage measuring accuracy: ±(0.03% + 8 digit)
DC current measuring accuracy: ±(0.08% + 8 digit)
Resistance measuring accuracy: ±(0.07%+8 digit)
кількість в упаковці: 1 шт
товар відсутній
C.A 5293 CA-5293.PDF
C.A 5293
Виробник: CHAUVIN ARNOUX
Category: Portable digital multimeters
Description: Digital multimeter; USB; colour,LCD; (100000); 5x/s; True RMS
Type of meter: digital multimeter
Kind of display used: colour; LCD
Display parameters: (100000)
Temperature measuring range: -200...800°C
Temperature measuring range (with K-type thermocouple): -40...1200°C
Temperature measurement accuracy: ±0.1%
Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Sampling: 5x/s
Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K
Interface: USB
Power supply: rechargeable battery Ni-MH AA 1,2V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
IP rating: IP67
Producer guarantee (months): 36
Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement
Standard equipment: case; mains battery charger; test leads; test probes; USB cable
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4
Software: included
Illumination: yes
Test: diodes
Continuity test: acoustic indication
Event memory: 10000
True effective value measurement: True RMS
Dimensions (W x H x D): 90x169x47.1mm
AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s)
Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s
DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV
AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV
Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz
Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
DC voltage measuring accuracy: ±(0.03% + 8 digit)
DC current measuring accuracy: ±(0.08% + 8 digit)
Resistance measuring accuracy: ±(0.07%+8 digit)
кількість в упаковці: 1 шт
товар відсутній
C.A 5293-BT CA-5293.PDF
C.A 5293-BT
Виробник: CHAUVIN ARNOUX
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth,USB; colour,LCD; (100000); 5x/s
Illumination: yes
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX801515; EX871515; EX872502; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Standard equipment: case; mains battery charger; test leads; test probes; USB cable
Measuring instrument features: auto and manual ranging; AUTO HOLD; automatic power-off; HOLD function; low input impedance function (LoZ); MIN/MAX/DIF/AVG function; PEAK function; selection of AC or AC+DC measurement
Type of meter: digital multimeter
Test: diodes
Continuity test: acoustic indication
Sampling: 5x/s
Temperature measuring range: -200...800°C
Temperature measuring range (with K-type thermocouple): -40...1200°C
Event memory: 30000
True effective value measurement: True RMS
Producer guarantee (months): 36
Measurement: AC current; AC voltage; capacitance; continuity; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Dimensions (W x H x D): 90x169x47.1mm
AC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; (20A <30s)
Resistance measuring range: 1Ω; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC current measuring range: 1mA; 10mA; 100mA; 1A; 10A; 20A < 30s
DC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV
AC voltage measuring range: 100mV; 1V; 10V; 100V; 1kV
Frequency measuring range: 10...100Hz; 1kHz; 10kHz; 100kHz; 1MHz; 5MHz
Capacitance measuring range: 1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x4
Software: included
Display parameters: (100000)
DC voltage measuring accuracy: ±(0.02% + 8 digit)
DC current measuring accuracy: ±(0.08% + 8 digit)
Resistance measuring accuracy: ±(0.07%+8 digit)
Temperature measurement accuracy: ±0.1%
Kind of display used: colour; LCD
Power supply: rechargeable battery Ni-MH AA 1,2V x4
IP rating: IP67
Interface: Bluetooth; USB
Kind of temperature sensor: Pt100; Pt1000; thermocouple J; thermocouple K
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
кількість в упаковці: 1 шт
на замовлення 3 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+70370.61 грн
3+ 66866.57 грн
C.A 6113 CA-6116N_DS.PDF
Виробник: CHAUVIN ARNOUX
Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD 5,7"; 320x240; IP53; Illumin: yes
IP rating: IP53
Measuring instrument features: long operating time up to 24 hours; programmable alarm thresholds; test leads resistance compensation
Power supply: rechargeable battery Ni-MH x1
Standard equipment: 3 crocodile clips; carrying case; hand strap; mains battery charger; neckstrap; remote probe; screen protector preventing scratching (set); test leads; test probes
Optional equipment: CA-C177; CA-C177A; CA-MN77
Loop impedance measuring accuracy: ±(5% + 2 digits)
Body dimensions: 280x190x128mm
Kind of display used: LCD 5,7"
Continuity test: acoustic indication; optical indication
Earthing resistance measuring accuracy: ±(2% + 2 digits)
Display resolution: 320x240
Weight with battery: 2.2kg
Loop impedance measurement: 100...500mΩ; 4Ω; 40Ω; 400Ω
Alias: P01145445
RCD test: AC, A and F-type RCDs; general purpose
Insulation resistance measuring ranges: 0.01MΩ...2GΩ
Test voltage: 50V; 100V; 250V; 500V; 1kV
Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010; IEC 61326-1
Illumination: yes
Type of meter: appliance meter
Measurement: AC current (with current clamps); AC voltage; continuity; DC voltage; earthing resistance; frequency; impedance; insulation resistance; leakage current; phase sequence; RCD tripping current; RCD tripping time; short circuit loop impedance; votlage drop
Earthing resistance measuring range: 500mΩ...40Ω; 15kΩ; 40kΩ
Battery/ rechargeable battery: rechargeable battery Ni-MH x1
кількість в упаковці: 1 шт
товар відсутній
C.A 6116N CA-6116N_DS.PDF CA-6116N_M.PDF
C.A 6116N
Виробник: CHAUVIN ARNOUX
Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; colour,LCD 5,7"; 320x240; USB; IP53
Type of meter: appliance meter
Interface: USB
Measurement: AC current (with current clamps); active power; AC voltage; continuity; DC voltage; earthing resistance; frequency; harmonics; impedance; insulation resistance; leakage current; phase sequence; RCD tripping current; RCD tripping time; short circuit loop impedance; votlage drop
Kind of display used: colour; LCD 5,7"
Display resolution: 320x240
Continuity test: acoustic indication; optical indication
IP rating: IP53
Body dimensions: 280x190x128mm
Weight with battery: 2.2kg
Power supply: rechargeable battery Li-Ion 10,8V x1
Standard equipment: 3 crocodile clips; carrying case; hand strap; mains battery charger; neckstrap; remote probe; screen protector preventing scratching (set); test leads; test probes; USB cable
Optional equipment: CA-C177A; CA-MN77
Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010; IEC 61326-1
Measuring instrument features: long operating time up to 30 hours; programmable alarm thresholds; test leads resistance compensation
Test voltage: 50V; 100V; 250V; 500V; 1kV
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: included
Insulation resistance measuring ranges: 0.01MΩ...2GΩ
Illumination: yes
Earthing resistance measuring range: 500mΩ...40Ω; 15kΩ; 40kΩ
Loop impedance measuring accuracy: ±(5% + 2 digit)
Earthing resistance measuring accuracy: ±(2% + 2 digit)
RCD test: AC, A and F-type RCDs; general purpose
Loop impedance measurement: 100...500mΩ; 4Ω; 40Ω; 400Ω
кількість в упаковці: 1 шт
на замовлення 2 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+139701.64 грн
C.A 6117 CA-6116N_DS.PDF CA-6116N_M.PDF
Виробник: CHAUVIN ARNOUX
Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; colour,LCD 5,7"; 320x240; USB; IP53
Type of meter: appliance meter
Interface: USB
Measurement: AC current (with current clamps); active power; AC voltage; continuity; DC voltage; earthing resistance; frequency; harmonics; impedance; insulation resistance; leakage current; phase sequence; RCD tripping current; RCD tripping time; short circuit loop impedance; votlage drop
Kind of display used: colour; LCD 5,7"
Display resolution: 320x240
Continuity test: acoustic indication; optical indication
IP rating: IP53
Body dimensions: 280x190x128mm
Weight with battery: 2.2kg
Power supply: rechargeable battery Li-Ion 10,8V x1
Standard equipment: 3 crocodile clips; carrying case; hand strap; mains battery charger; neckstrap; remote probe; screen protector preventing scratching (set); test leads; test probes; USB cable
Optional equipment: CA-C177A; CA-MN77
Conform to the norm: CAT III 600V; CAT IV 300V; EN 61010; IEC 61326-1
Measuring instrument features: built-in fuse table; long operating time up to 30 hours; programmable alarm thresholds; test leads resistance compensation
Test voltage: 50V; 100V; 250V; 500V; 1kV
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: included
Insulation resistance measuring ranges: 0.01MΩ...2GΩ
Illumination: yes
Earthing resistance measuring range: 500mΩ...40Ω; 15kΩ; 40kΩ
Loop impedance measuring accuracy: ±(5% + 2 digit)
Earthing resistance measuring accuracy: ±(2% + 2 digit)
RCD test: AC, B, B+, EV, A and F-type RCDs; general purpose
Loop impedance measurement: 100...500mΩ; 4Ω; 40Ω; 400Ω
кількість в упаковці: 1 шт
товар відсутній
C.A 6131 HLHBIX5T.PDF CA-6116N_DS.PDF CA-6116N_M.PDF
C.A 6131
Виробник: CHAUVIN ARNOUX
Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; VAC: 0÷800V; ±(1%+2digit); IP54
Dimensions: 223x126x70mm
Measuring instrument features: Pass/Fail function
Standard equipment: 3 crocodile clips; carrying case; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1
Measurement: AC voltage; continuity; insulation resistance; phase sequence; RCD tripping time; resistance
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x6
AC voltage measuring range: 0...800V
Resistance measuring range: 1...10Ω; 100kΩ
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Measurement memory: 2970
IP rating: IP54
Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1
Bargraph: yes
Loop impedance measuring range: 100mΩ...1Ω; 400Ω
Insulation resistance measuring ranges: 0...100MΩ; 1GΩ
AC voltage measuring accuracy: ±(1% + 2 digit)
Illumination: yes
Type of meter: appliance meter
Continuity test: <10Ω
RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+57367.09 грн
C.A 6133 HLHBIX5T.PDF
C.A 6133
Виробник: CHAUVIN ARNOUX
Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; VAC: 2÷550V; 30÷1000Hz; Bluetooth
Dimensions: 223x126x70mm
Measuring instrument features: automatic generation of PDF file with recorded data; magnetized casing; Pass/Fail function
Standard equipment: 3 crocodile clips; battery charger/power supply; carrying case; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1; USB cable
Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance
Kind of display used: LCD
Interface: Bluetooth
Power supply: rechargeable battery Ni-MH AA x6
Software: dedicated mobile app
AC voltage measuring range: 2...550V
Resistance measuring range: 1...10Ω; 100kΩ
Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6
Measurement memory: 2970
IP rating: IP54
Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1
Bargraph: yes
Loop impedance measuring range: 100mΩ...1Ω; 400Ω
Frequency measuring range: 30...1000Hz
Earthing resistance measuring range: 500mΩ...100Ω; 1kΩ; 2kΩ
Insulation resistance measuring ranges: 0...100MΩ; 1GΩ
Frequency measuring accuracy: ±(0.1%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Illumination: yes
Type of meter: appliance meter
Continuity test: <10Ω
RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+67207.29 грн
C.A 6133 LAUNCH KIT
Виробник: CHAUVIN ARNOUX
Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; VAC: 2÷550V; 30÷1000Hz; Bluetooth
Illumination: yes
IP rating: IP54
Dimensions: 223x126x70mm
Measurement memory: 2970
Standard equipment: 3 crocodile clips; battery charger/power supply; carrying case; continuity rod; kit for earth ground resistance measurement 15m; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1; USB cable
Measuring instrument features: automatic generation of PDF file with recorded data; magnetized casing; Pass/Fail function
Type of meter: appliance meter
Continuity test: <10Ω
RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose
Bargraph: yes
Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance
Resistance measuring range: 1...10Ω; 100kΩ
Loop impedance measuring range: 100mΩ...1Ω; 400Ω
AC voltage measuring range: 2...550V
Frequency measuring range: 30...1000Hz
Earthing resistance measuring range: 500mΩ...100Ω; 1kΩ; 2kΩ
Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6
Software: dedicated mobile app
Insulation resistance measuring ranges: 0...100MΩ; 1GΩ
Frequency measuring accuracy: ±(0.1%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Kind of display used: LCD
Power supply: rechargeable battery Ni-MH AA x6
Interface: Bluetooth
Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1
кількість в упаковці: 1 шт
на замовлення 2 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+79645.96 грн
C.A 6165
Виробник: CHAUVIN ARNOUX
Category: Electrical Safety Testers
Description: Safety analyzer; Interface: Bluetooth,RS232; 435x292x155mm
Type of meter: safety analyzer
Supply voltage: 100...240V AC
IP rating: IP40
Dimensions: 435x292x155mm
Interface: Bluetooth; RS232
Kind of display used: LCD TFT
Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance
Software: dedicated mobile app
Insulation resistance measuring ranges: 0...20MΩ; 100MΩ
Measurement memory: 6000
Display resolution: 480x272
Standard equipment: carrying case; crocodile clips; EURO mains power cable; manual (CD); probe; RS232 cable; test leads; USB cable
Measuring instrument features: automatic generation of PDF file with recorded data; magnetized casing; Pass/Fail function
RCD test: 10mA, 30mA, 100mA, 300mA, 500mA, 1000mA ; general purpose
Test voltage: 50V; 100V; 250V; 500V; 1kV
кількість в упаковці: 1 шт
товар відсутній
C.A 6240 6240dte_EN.pdf
C.A 6240
Виробник: CHAUVIN ARNOUX
Category: Miliohmmeters
Description: Milli-ohm meter; LCD; R range: 400uΩ÷400Ω; ±(0.25%+2digit)
Type of meter: milli-ohm meter
Resistance measuring range: 400µΩ...400Ω
Resistance measuring accuracy: ±(0.25%+2 digit)
Measuring instrument features: automatic power-off
Conform to the norm: CAT III 50V; EN 61010
Power supply: rechargeable battery Ni-MH x1
Dimensions: 273x247x280mm
Standard equipment: Kelvin test leads; mains cable; USB cable; user's manual
Test current: 10mA @ 4Ω...39.99Ω; 10mA @ 40Ω...399.9Ω; 100mA @ 400mΩ...3999mΩ; 1A @ 4µΩ...39.99mΩ; 1A @ 40mΩ...399.9mΩ; 10A @ 5µΩ...3.999µΩ
Battery/ rechargeable battery: rechargeable battery Ni-MH x1
Software: included
Kind of display used: LCD
Interface: USB
кількість в упаковці: 1 шт
товар відсутній
Обрати Сторінку:    << Попередня Сторінка ]  1 2 3 4 5 6 7 8 9 10 11 12  Наступна Сторінка >> ]