Продукція > FLUKE > FLUKE 8846A/SU
FLUKE 8846A/SU

FLUKE 8846A/SU


Виробник: FLUKE
Category: Benchtop digital multimeters
Description: Benchtop multimeter; VFD; Sampling: 1000x/s; VDC: 1V,10V,100V,1kV
Supply voltage: 230V AC
Operating temperature: 0...55°C
Temperature measuring range: -200...600°C
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5519A; POM-5901B/POM; POM-6204A
Dimensions: 88x215x293mm
Interface: Ethernet; IEEE-488; RS232; USB
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Software: Fluke View Forms
Kind of display used: VFD
Kind of output connector: D-Sub female socket; GPIB socket; RJ45 socket; USB A socket
Standard equipment: FLK-884X-USB RS232 to USB adapter; FLK-FVF-UG - FlukeView Forms Basic software upgrade; mains cable; spare fuse; test leads FLK-TL71
Measuring instrument features: measures two different parameters of the same signal; MIN/MAX/MEAN/StdDv function; real time clock; TrendPlot, Histogram - graphical visualisation of measurement results
Type of meter: benchtop multimeter
Continuity test: acoustic indication; <1Ω; <1kΩ
Sampling: 1000x/s
Temperature measurement resolution: 0.01°C
Plug variant: EU
Bandwidth for AC voltage measurements: 3...300kHz
AC current measuring range: 1mA; 10mA; 100mA; 400mA; 1A; 3A; 10A
Resistance measuring range: 10µΩ...10Ω; 100Ω; 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ; 1GΩ
Bandwidth for AC current measurements: 3...10kHz
DC current measuring range: 100pA...100µA; 1mA; 100mA; 400mA; 1A; 3A; 10A
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 100nV...100mV; 1V; 10V; 100V; 1kV
Frequency measuring range: 3...1MHz
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
Diode test: 1mA @10V
Display parameters: 6,5 digit
Frequency measuring accuracy: ±0.01%
Capacitance measuring accuracy: ±1%
AC current measuring accuracy: ±(0.1% + 0.04% range)
DC voltage measuring accuracy: ±(0.0024% + 0.0005% range)
DC current measuring accuracy: ±(0.05% + 0.005% range)
AC voltage measuring accuracy: ±(0.06% + 0.03% range)
Resistance measuring accuracy: ±(0.01%+0.001% range)
Temperature measurement accuracy: ±0.06%
Conform to the norm: CAT I 1000V; CAT II 600V; EN 61010
на замовлення 1 шт:

термін постачання 21-30 дні (днів)
Кількість Ціна без ПДВ
1+127315.28 грн
Відгуки про товар
Написати відгук

Технічний опис FLUKE 8846A/SU FLUKE

Category: Benchtop digital multimeters, Description: Benchtop multimeter; VFD; Sampling: 1000x/s; VDC: 1V,10V,100V,1kV, Supply voltage: 230V AC, Operating temperature: 0...55°C, Temperature measuring range: -200...600°C, Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5519A; POM-5901B/POM; POM-6204A, Dimensions: 88x215x293mm, Interface: Ethernet; IEEE-488; RS232; USB, Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature, Software: Fluke View Forms, Kind of display used: VFD, Kind of output connector: D-Sub female socket; GPIB socket; RJ45 socket; USB A socket, Standard equipment: FLK-884X-USB RS232 to USB adapter; FLK-FVF-UG - FlukeView Forms Basic software upgrade; mains cable; spare fuse; test leads FLK-TL71, Measuring instrument features: measures two different parameters of the same signal; MIN/MAX/MEAN/StdDv function; real time clock; TrendPlot, Histogram - graphical visualisation of measurement results, Type of meter: benchtop multimeter, Continuity test: acoustic indication; .

Інші пропозиції FLUKE 8846A/SU за ціною від 152778.34 грн до 152778.34 грн

Фото Назва Виробник Інформація Доступність
Ціна без ПДВ
FLUKE 8846A/SU FLUKE 8846A/SU Виробник : FLUKE Category: Benchtop digital multimeters
Description: Benchtop multimeter; VFD; Sampling: 1000x/s; VDC: 1V,10V,100V,1kV
Supply voltage: 230V AC
Operating temperature: 0...55°C
Temperature measuring range: -200...600°C
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5519A; POM-5901B/POM; POM-6204A
Dimensions: 88x215x293mm
Interface: Ethernet; IEEE-488; RS232; USB
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Software: Fluke View Forms
Kind of display used: VFD
Kind of output connector: D-Sub female socket; GPIB socket; RJ45 socket; USB A socket
Standard equipment: FLK-884X-USB RS232 to USB adapter; FLK-FVF-UG - FlukeView Forms Basic software upgrade; mains cable; spare fuse; test leads FLK-TL71
Measuring instrument features: measures two different parameters of the same signal; MIN/MAX/MEAN/StdDv function; real time clock; TrendPlot, Histogram - graphical visualisation of measurement results
Type of meter: benchtop multimeter
Continuity test: acoustic indication; <1Ω; <1kΩ
Sampling: 1000x/s
Temperature measurement resolution: 0.01°C
Plug variant: EU
Bandwidth for AC voltage measurements: 3...300kHz
AC current measuring range: 1mA; 10mA; 100mA; 400mA; 1A; 3A; 10A
Resistance measuring range: 10µΩ...10Ω; 100Ω; 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ; 1GΩ
Bandwidth for AC current measurements: 3...10kHz
DC current measuring range: 100pA...100µA; 1mA; 100mA; 400mA; 1A; 3A; 10A
DC voltage measuring range: 1V; 10V; 100V; 1kV
AC voltage measuring range: 100nV...100mV; 1V; 10V; 100V; 1kV
Frequency measuring range: 3...1MHz
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
Diode test: 1mA @10V
Display parameters: 6,5 digit
Frequency measuring accuracy: ±0.01%
Capacitance measuring accuracy: ±1%
AC current measuring accuracy: ±(0.1% + 0.04% range)
DC voltage measuring accuracy: ±(0.0024% + 0.0005% range)
DC current measuring accuracy: ±(0.05% + 0.005% range)
AC voltage measuring accuracy: ±(0.06% + 0.03% range)
Resistance measuring accuracy: ±(0.01%+0.001% range)
Temperature measurement accuracy: ±0.06%
Conform to the norm: CAT I 1000V; CAT II 600V; EN 61010
кількість в упаковці: 1 шт
на замовлення 1 шт:
термін постачання 7-14 дні (днів)
Кількість Ціна без ПДВ
1+152778.34 грн